EVALUATION OF LOPHINE DERIVATIVES AS CHEMILUMINOGENS BY A FLOW-INJECTION METHOD

被引:94
作者
NAKASHIMA, K
YAMASAKI, H
KURODA, N
AKIYAMA, S
机构
[1] School of Pharmaceutical Sciences, Nagasaki University, Nagasaki, 852
关键词
CHEMILUMINESCENCE; FLOW INJECTION; LOPHINE;
D O I
10.1016/0003-2670(94)00360-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and convenient method for the evaluation of lophine (2,4,5-triphenylimidazole) derivatives as to their chemiluminescence efficiency was developed by using a flow-injection technique. Standard solutions of lophine derivatives were injected into a flow line containing a carrier solution (1.5 X 10(-4) M cobalt(II) containing 0.2% hydroxylammonium chloride in 75% methanol), which was successively combined with a flow line containing 100 mM hydrogen peroxide in H2O and a flow line containing 1.0 M KOH in H2O, and the chemiluminescence generated was monitored. Addition of hydroxylammonium chloride into a carrier solution resulted in a significant increase in chemiluminescence. Calibration graphs for eighteen derivatives were prepared and the relative chemiluminescence intensities were estimated from the slopes of these graphs. Among the derivatives, the compounds substituted by OCH, at the 2- and S-positions, and COOH, COCl, CONHNH2 and CONHNHCO(CH2)(4)CH3 at the 4-position on the phenyl ring at the 2-position of the imidazole skeleton showed large chemiluminescence intensities which are comparable to that of lophine. The detection limit of lophine was 72 fmol per injection at a signal-to-noise ratio of 2.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 13 条
[1]   MECHANISM OF CHEMILUMINESCENCE OF 2,4,5-TRIPHENYLIMIDAZOLE [J].
HAYASHI, T ;
MAEDA, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1962, 35 (12) :2057-2058
[2]   LOPHINE CHEMI-LUMINESCENCE FOR DETERMINATION OF CHROMIUM(VI) BY CONTINUOUS-FLOW METHOD [J].
KAMIDATE, T ;
YAMAGUCHI, K ;
SEGAWA, T ;
WATANABE, H .
ANALYTICAL SCIENCES, 1989, 5 (04) :429-433
[3]   MAXIMIZATION OF THE CHEMILUMINESCENCE EFFICIENCY OF 1,4,5-TRIARYLHYDROPEROXY-4H-ISOIMIDAZOLES [J].
KIMURA, M ;
NISHIKAWA, H ;
KURA, H ;
LIM, H ;
WHITE, EH .
CHEMISTRY LETTERS, 1993, (03) :505-508
[4]  
KURODA N, 1993, BIOL PHARM BULL, V16, P220
[5]   LOPHINE CHEMI-LUMINESCENCE FOR METAL-ION DETERMINATIONS [J].
MACDONALD, A ;
CHAN, KW ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2077-2082
[6]   ION-EXCHANGE SEPARATION OF COBALT FROM ALKALINE-EARTH AND SELECTED TRANSITION-METALS WITH LOPHINE CHEMI-LUMINESCENCE DETECTION [J].
MARINO, DF ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :292-294
[7]   DETERMINATION OF COBALT BY LOPHINE CHEMI-LUMINESCENCE [J].
MARINO, DF ;
WOLFF, F ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1979, 51 (12) :2051-2053
[8]   SYNTHESIS AND EVALUATION OF ARYL OXALATES AS PEROXYOXALATE CHEMI-LUMINESCENCE REAGENTS [J].
NAKASHIMA, K ;
MAKI, K ;
AKIYAMA, S ;
WEI, HW ;
TSUKAMOTO, Y ;
IMAI, K .
ANALYST, 1989, 114 (11) :1413-1416
[9]   EVALUATION OF PYRIMIDO[5,4-D]PYRIMIDINE DERIVATIVES AS PEROXYOXALATE CHEMILUMINESCENCE REAGENTS USING A FLOW-INJECTION SYSTEM [J].
NAKASHIMA, K ;
MAKI, K ;
AKIYAMA, S ;
IMAI, K .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (03) :105-107
[10]   2-(4-HYDRAZINOCARBONYLPHENYL)-4,5-DIPHENYLIMIDAZOLE AS A VERSATILE FLUORESCENT DERIVATIZATION REAGENT FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF FREE FATTY-ACIDS [J].
NAKASHIMA, K ;
TAGUCHI, Y ;
KURODA, N ;
AKIYAMA, S ;
DUAN, GL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (01) :1-8