2ND DERIVATIVE SYNCHRONOUS SCANNING FLUORESCENCE SPECTROMETRY AS A SENSITIVE DETECTION TECHNIQUE IN IMMUNOASSAYS - APPLICATION TO THE DETERMINATION OF ALPHA-FETOPROTEIN

被引:21
作者
LIANIDOU, ES
IOANNOU, PC
SACHARIDOU, E
机构
[1] University of Athens, Laboratory of Analytical Chemistry, Zografou, 15771 Athens, Panepistimiopolis
关键词
2ND-DERIVATIVE SYNCHRONOUS FLUORESCENCE SPECTROMETRY; IMMUNOASSAY; TERBIUM CHELATES; ALPHA-FETOPROTEIN; ENZYME AMPLIFIED LANTHANIDE LUMINESCENCE IMMUNOASSAY;
D O I
10.1016/0003-2670(94)80051-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Second derivative synchronous (scanning) fluorescence spectrometry (SDSFS) has been used for the first time as an alternative to time-resolved fluorescence for the detection of Tb3+ chelates. This approach minimizes the background signal by taking advantage of the large Stokes shift properties of Tb3+ chelates and offers high sensitivity by narrowing the spectral bands. The analytical performance of this detection technique has been evaluated by choosing the well-defined enzyme-amplified lanthanide luminescence (EALL) immunoassay of alpha-fetoprotein (AFP) as a model. Monoclonal ''capture'' antibodies and monoclonal biotin-labelled antibodies in a ''sandwich-type'' assay configuration in a microwell format have been used. Alkaline phosphatase (ALP) conjugated to an antibiotin antibody was used as an enzyme label. ALP cleaves phosphate from salicylphosphate to produce salicylic acid which forms a highly fluorescent ternary complex with Tb3+ and EDTA, which is monitored by SDSFS. The method allows the measurement of AFP with a limit of detection of 2 pg ml(-1), coefficients of variation in the range 4.5-9.9% and mean recovery from four pooled serum samples at two concentration levels equal to 94 +/- 11%.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 19 条
[11]   SIMULTANEOUS DETERMINATION OF ACETYLSALICYLIC AND SALICYLIC ACIDS IN HUMAN SERUM AND ASPIRIN FORMULATIONS BY 2ND-DERIVATIVE SYNCHRONOUS FLUORESCENCE SPECTROMETRY [J].
KONSTANTIANOS, DG ;
IOANNOU, PC ;
EFSTATHIOU, CE .
ANALYST, 1991, 116 (04) :373-378
[12]   SIMULTANEOUS DETERMINATION OF ACETYLSALICYLIC-ACID AND ITS MAJOR METABOLITES IN HUMAN SERUM BY 2ND-DERIVATIVE SYNCHRONOUS FLUORESCENCE SPECTROMETRY [J].
KONSTANTIANOS, DG ;
IOANNOU, PC .
ANALYST, 1992, 117 (05) :877-882
[13]  
Kricka L.L., 1992, NONISOTOPIC DNA PROB
[14]   PREDICTION OF PEAK WAVELENGTHS AND INTENSITIES IN SYNCHRONOUSLY EXCITED FLUORESCENCE EMISSION-SPECTRA [J].
LLOYD, JBF ;
EVETT, IW .
ANALYTICAL CHEMISTRY, 1977, 49 (12) :1710-1715
[15]   SYNCHRONIZED EXCITATION OF FLUORESCENCE EMISSION SPECTRA [J].
LLOYD, JBF .
NATURE-PHYSICAL SCIENCE, 1971, 231 (20) :64-&
[16]   ANALYSIS OF BINARY AND TERNARY MIXTURES OF TITANIUM, ZIRCONIUM, AND HAFNIUM BY DERIVATIVE SYNCHRONOUS FLUORESCENCE SPECTROMETRY [J].
RUBIO, S ;
GOMEZHENS, A ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1985, 57 (06) :1101-1106
[17]  
SANCHEZ FG, 1985, ANAL CHIM ACTA, V167, P217
[18]   SMOOTHING + DIFFERENTIATION OF DATA BY SIMPLIFIED LEAST SQUARES PROCEDURES [J].
SAVITZKY, A ;
GOLAY, MJE .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1627-&
[19]   MULTICOMPONENT ANALYSIS BY SYNCHRONOUS LUMINESCENCE SPECTROMETRY [J].
VO-DINH, T .
ANALYTICAL CHEMISTRY, 1978, 50 (03) :396-401