THE FEMORAL COMPONENT IN TOTAL HIP-ARTHROPLASTY - 6 TO 8-YEAR FOLLOW-UP OF 100 CONSECUTIVE PATIENTS AFTER USE OF A 3RD-GENERATION CEMENTING TECHNIQUE

被引:100
作者
OISHI, CS [1 ]
WALKER, RH [1 ]
COLWELL, CW [1 ]
机构
[1] SCRIPPS CLIN & RES FDN, DIV ORTHOPAED SURG, LA JOLLA, CA 92037 USA
关键词
D O I
10.2106/00004623-199408000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One hundred consecutive patients had a primary unilateral total hip arthroplasty with use of a single design of the femoral component (Harris Precoat), inserted,vith a so-called third generation cementing technique, between July 1985 and June 1987. There were seventy-four women and twenty-six men. The mean age at the time of the operation was seventy one years (range, forty-one to ninety-two years) and the mean weight was seventy kilograms (range, forty-eight to 105 kilograms). Eleven of the 100 patients died during the followup period, all,vith the implant in place. Of the eighty-nine surviving patients, one had a revision arthroplasty for aseptic loosening. The mean duration of clinical follow-up for the remaining eighty-eight patients was seven years (range, six to eight years). The mean Harris hip score at the latest follow-up evaluation was 91 points (range, 68 to 97 points). Of the eighty-eight patients, eighty-five (97 per cent) had a good or excellent result. Radiographic follow-up was performed for eighty-one patients; none had evidence of loosening of the stem, and five (6 per cent) had endosteal cavitation but were asymptomatic. The rate of failure (loosening or revision) of the femoral component in the entire series was 1 per cent (one hip). The low rate of failure and the maintenance of good and excellent clinical and radiographic results during this period of follow-up are consistent,vith reports from other institutions. This strengthens the argument to retain or widen the existing indications for the insertion of a femoral stem with cement in primary total hip arthroplasty.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 30 条
[11]   FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION [J].
HARRIS, WH ;
MCCARTHY, JC ;
ONEILL, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1063-1067
[12]   LOOSENING OF THE FEMORAL COMPONENT AFTER USE OF THE MEDULLARY-PLUG CEMENTING TECHNIQUE - FOLLOW-UP NOTE WITH A MINIMUM 5-YEAR FOLLOW-UP [J].
HARRIS, WH ;
MCGANN, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1064-1066
[13]   THE POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS, INSERTED WITHOUT CEMENT - RESULTS AFTER 5 TO 7 YEARS IN A PROSPECTIVE-STUDY [J].
HEEKIN, RD ;
CALLAGHAN, JJ ;
HOPKINSON, WJ ;
SAVORY, CG ;
XENOS, JS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :77-91
[14]   THE INITIATION OF FAILURE IN CEMENTED FEMORAL COMPONENTS OF HIP ARTHROPLASTIES [J].
JASTY, M ;
MALONEY, WJ ;
BRAGDON, CR ;
OCONNOR, DO ;
HAIRE, T ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :551-558
[15]   INGROWTH OF BONE IN FAILED FIXATION OF POROUS-COATED FEMORAL COMPONENTS [J].
JASTY, M ;
BRAGDON, CR ;
MALONEY, WJ ;
HAIRE, T ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (09) :1331-1337
[16]   CLINICAL AND RADIOGRAPHIC EVALUATION OF TOTAL HIP-REPLACEMENT - A STANDARD SYSTEM OF TERMINOLOGY FOR REPORTING RESULTS [J].
JOHNSTON, RC ;
FITZGERALD, RH ;
HARRIS, WH ;
POSS, R ;
MULLER, ME ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :161-168
[17]   RESULTS OF THE HARRIS-GALANTE CEMENTLESS HIP-PROSTHESIS [J].
KIM, YH ;
KIM, VEM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :83-87
[18]   BONE LYSIS IN WELL-FIXED CEMENTED FEMORAL COMPONENTS [J].
MALONEY, WJ ;
JASTY, M ;
ROSENBERG, A ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :966-970
[19]   PRIMARY TOTAL HIP RECONSTRUCTION WITH A TITANIUM FIBER-COATED PROSTHESIS INSERTED WITHOUT CEMENT [J].
MARTELL, JM ;
PIERSON, RH ;
JACOBS, JJ ;
ROSENBERG, AG ;
MALEY, M ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (04) :554-571
[20]   THE EFFECT OF IMPROVED CEMENTING TECHNIQUES ON COMPONENT LOOSENING IN TOTAL HIP-REPLACEMENT - AN 11-YEAR RADIOGRAPHIC REVIEW [J].
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05) :757-760