COMPARISON OF METHODS TO PREVENT RESTRICTOR PLUGGING DURING OFF-LINE SUPERCRITICAL EXTRACTION

被引:48
作者
BURFORD, MD
HAWTHORNE, SB
MILLER, DJ
BRAGGINS, T
机构
[1] UNIV N DAKOTA,ENERGY & ENVIRONM RES CTR,GRAND FORKS,ND 58202
[2] MEAT IND RES INST NEW ZEALAND,HAMILTON,NEW ZEALAND
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 609卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80176-U
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Real-world environmental samples which contain high concentrations of water and/or extractable matrix components frequently cause intermittent or irreversible plugging of capillary flow restrictors during off-line supercritical fluid extraction. Heating the entire restrictor at 50-degrees-C produces a constant extraction flow-rate (+/-0.03 ml/min) for such samples, but poor collection efficiencies (30-65% recovery for polycyclic aromatic hydrocarbons) were obtained because the supercritical fluid could not be depressurized directly into the collection solvent. While the collection efficiency was improved (80-90%) by nebulizing an organic solvent with the restrictor effluent, a simpler method was to heat all but the last 3 cm of the restrictor and to depressurize the extract directly in the collection solvent. Depending on the sample matrix, restrictor heater temperatures ranging from 50 to 200-degrees-C were required to avoid restrictor plugging. With proper heating, constant extraction flow-rates (+/-0.07 ml/min) and high collection efficiencies (90-100%) for polycyclic aromatic hydrocarbons and n-alkanes as volatile as n-octane were achieved.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 22 条
  • [1] Campbell R. M., 1989, J MICROCOLUMN SEP, V1, P302, DOI 10.1002/mcs.1220010609
  • [2] SUPERCRITICAL FLUID FRACTIONATION OF PETROLEUM-DERIVED AND COAL-DERIVED MIXTURES
    CAMPBELL, RM
    LEE, ML
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (11) : 2247 - 2251
  • [3] APPARATUS FOR SUPERCRITICAL FLUID CHROMATOGRAPHY WITH CARBON-DIOXIDE AS MOBILE PHASE
    JENTOFT, RE
    GOUW, TH
    [J]. ANALYTICAL CHEMISTRY, 1972, 44 (04) : 681 - &
  • [4] JONES B, COMMUNICATION
  • [5] EFFECTS OF COLLECTION SOLVENT PARAMETERS AND EXTRACTION CELL GEOMETRY ON SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES
    LANGENFELD, JJ
    BURFORD, MD
    HAWTHORNE, SB
    MILLER, DJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2): : 297 - 307
  • [6] MCNAIR HM, 1991, AM LAB, V23, pD24
  • [7] PORTER NL, 1991, JAN P INT S SUP FLUI, P127
  • [8] SAITO M, 1989, RSC CHROMATOGRAPHY M, P203
  • [9] SANDRA P, 1990, HRC-J HIGH RES CHROM, V13, P284
  • [10] PREPARATION AND ANALYSIS OF A MARINE SEDIMENT REFERENCE MATERIAL FOR THE DETERMINATION OF TRACE ORGANIC-CONSTITUENTS
    SCHANTZ, MM
    BENNER, BA
    CHESLER, SN
    KOSTER, BJ
    HEHN, KE
    STONE, SF
    KELLY, WR
    ZEISLER, R
    WISE, SA
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04): : 501 - 514