QUANTITATIVE INVESTIGATION OF IN-VITRO FLOW USING 3-DIMENSIONAL COLOR DOPPLER ULTRASOUND

被引:30
作者
GUO, ZY [1 ]
MOREAU, M [1 ]
RICKEY, DW [1 ]
PICOT, PA [1 ]
FENSTER, A [1 ]
机构
[1] UNIV WESTERN ONTARIO, DEPT MED BIOPHYS, LONDON, ON, CANADA
基金
英国医学研究理事会;
关键词
3D COLOR DOPPLER ULTRASOUND; QUANTITATIVE FLOW MEASUREMENT; VASCULAR PHANTOM; WALL SHEAR STRESS; FLOW VISUALIZATION; VELOCITY ACCURACY;
D O I
10.1016/0301-5629(95)00007-E
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A quantitative in vitro flow study was performed by using a three-dimensional colour Doppler imaging system. This system was based on a clinical ultrasound instrument with its transducer mounted on a motor-driven translation stage. A vascular and tissue-mimicking phantom containing two wall-less vessels, one normal and another stenotic, was used to quantify the measurement accuracy of the flow velocity and the flow field. Steady state flows, having Reynolds numbers ranging between 460 and 1300, were generated by a computer-controlled positive displacement pump. Effects of the parameter settings of the ultrasound instrument on results of the estimation of flow field were also studied. Experimental results show that our three-dimensional colour Doppler system's velocity accuracy was better than 7% of the Nyquist velocity and its spatial accuracy was better than 0.5 mm. The system showed a good correlation (r = 0.999) between the estimated and the true mean flow velocity, and a good correlation (r = 0.998) between the estimated maximum and the true mean how velocity. This study is our first step toward validating the measurement of the three-dimensional velocity and wall shear stress distributions by using three-dimensional colour Doppler ultrasound.
引用
收藏
页码:807 / 816
页数:10
相关论文
共 28 条
[1]   TWO-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY IN ACUTE MYOCARDIAL-INFARCTION AND ITS COMPLICATIONS [J].
ASSMANN, PE ;
ROELANDT, JRTC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (09) :507-517
[2]   IMPORTANCE OF TECHNICAL VARIABLES FOR QUANTITATIVE MEASUREMENTS BY COLOR DOPPLER IMAGING [J].
BAUMGARTNER, H ;
SCHIMA, H ;
KUHN, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (04) :314-315
[3]  
CARO CG, 1977, CARDIOVASCULAR FLOW, P473
[4]   THE EFFECT OF COMPLIANCE ON WALL SHEAR IN CASTS OF A HUMAN AORTIC BIFURCATION [J].
DUNCAN, DD ;
BARGERON, CB ;
BORCHARDT, SE ;
DETERS, OJ ;
GEARHART, SA ;
MARK, FF ;
FRIEDMAN, MH .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :183-188
[5]  
EVANS DS, 1989, DOPPLER ULTRASOUND P, P9
[7]   LOCALIZATION OF ATHEROSCLEROTIC LESIONS IN THE BIFURCATION OF THE MAIN LEFT CORONARY-ARTERY [J].
GROTTUM, P ;
SVINDLAND, A ;
WALLOE, L .
ATHEROSCLEROSIS, 1983, 47 (01) :55-62
[8]   COMPUTER-CONTROLLED POSITIVE DISPLACEMENT PUMP FOR PHYSIOLOGICAL FLOW SIMULATION [J].
HOLDSWORTH, DW ;
RICKEY, DW ;
DRANGOVA, M ;
MILLER, DJM ;
FENSTER, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (06) :565-570
[9]   QUANTITATIVE COLOR FLOW IMAGING TO MEASURE THE 2-DIMENSIONAL DISTRIBUTION OF BLOOD-FLOW VELOCITY AND THE FLOW-RATE [J].
KITABATAKE, A ;
TANOUCHI, J ;
YOSHIDA, Y ;
MASUYAMA, T ;
UEMATSU, M ;
KAMADA, T .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1990, 54 (03) :304-308
[10]   INVIVO RELATION BETWEEN CINEANGIOGRAPHIC JET WIDTH AND JET WIDTH IMAGED BY COLOR-CODED DOPPLER [J].
KLEWER, SE ;
LLOYD, TR ;
GOLDBERG, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (19) :1399-1401