COMPARISON OF DIFFERENT BIOSENSOR SYSTEMS SUITABLE FOR BIOPROCESS MONITORING

被引:12
作者
BILITEWSKI, U
DREWES, W
NEERMANN, J
SCHRADER, J
SURKOW, R
SCHMID, RD
BRADLEY, J
机构
[1] Department of Enzyme Technology, Gesellschaft für Biotechnologische Forschung (GBF), Braunschweig
关键词
ENZYME ELECTRODE; FLOW INJECTION ANALYSIS; FIA; AMPEROMETRIC BIOSENSOR; MEDIATOR; IN SITU ELECTRODE; ENZYME REACTOR; H2O2;
D O I
10.1016/0168-1656(93)90072-U
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To achieve effective bioprocess monitoring, sensing systems are required which are suitable for an on-line determination of substrates, inhibitors, nutrients or products. Such devices may utilise biochemical principles, i.e. the specific interaction of biochemical receptors with their surroundings. They can be constructed either as in situ sensors or as flow-through sensors connected to the process via sampling devices. Hence, characteristic features of an in situ glucose electrode are described, e.g. analytical range, sensitivity and stability. The sensor was based on mediated electron transfer from the enzyme glucose oxidase to the graphite electrode, the mediators being tetrathiafulvalene (TTF) or dimethylferrocene (DMF). Additionally, various flow injection analysis (FIA) systems based on oxidases, which were immobilised either on controlled pore glass or in a membrane, were characterised with respect to analytical ranges and sensitivities and applied to glucose, lactate and glutamate determinations in off-line samples taken from an animal cell cultivation.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 9 条
[1]  
BILITEWSKI U, 1991, 9 DECH JAHR TAG BIOT
[2]   RAPID-DETERMINATION OF THE GLUCOSE CONTENT OF MOLASSES USING A BIOSENSOR [J].
BRADLEY, J ;
KIDD, AJ ;
ANDERSON, PA ;
DEAR, AM ;
ASHBY, RE ;
TURNER, APF .
ANALYST, 1989, 114 (03) :375-379
[3]   OPTIMIZATION OF A BIOSENSOR FOR INSITU FERMENTATION MONITORING OF GLUCOSE-CONCENTRATION [J].
BRADLEY, J ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (08) :669-674
[4]  
Bradley J., 1991, PROCESS CONTR QUAL, V1, P157
[5]   ONLINE DETERMINATION OF GLUCOSE AND LACTATE CONCENTRATIONS IN ANIMAL-CELL CULTURE BASED ON FIBER OPTIC DETECTION OF OXYGEN IN FLOW-INJECTION ANALYSIS [J].
DREMEL, BAA ;
LI, SY ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (02) :133-139
[6]   ONLINE DETERMINATION OF GLUCOSE IN BIOTECHNOLOGICAL PROCESSES - COMPARISON BETWEEN FIA AND AN INSITU ENZYME ELECTRODE [J].
FILIPPINI, C ;
SONNLEITNER, B ;
FIECHTER, A ;
BRADLEY, J ;
SCHMID, R .
JOURNAL OF BIOTECHNOLOGY, 1991, 18 (1-2) :153-160
[7]  
NENTWIG J, 1985, Patent No. 222129
[8]   FLOW-INJECTION ANALYSIS AND ENZYME ELECTRODES FOR BIOPROCESS MONITORING [J].
STOCKLEIN, W ;
BRADLEY, J ;
BILITEWSKI, U ;
SCHMID, RD .
CHEMIE INGENIEUR TECHNIK, 1991, 63 (06) :555-564
[9]   MEDIATED ENZYME ELECTRODE FOR THE DETERMINATION OF L-GLUTAMATE [J].
VAHJEN, W ;
BRADLEY, J ;
BILITEWSKI, U ;
SCHMID, RD .
ANALYTICAL LETTERS, 1991, 24 (08) :1445-1452