A TEST TO MEASURE LIFT CAPACITY OF PHYSICALLY IMPAIRED ADULTS .1. DEVELOPMENT AND RELIABILITY TESTING

被引:40
作者
MATHESON, LN
MOONEY, V
GRANT, JE
AFFLECK, M
HALL, H
MELLES, T
LICHTER, RL
MCINTOSH, G
机构
[1] UNIV WASHINGTON,SCH MED,PROGRAM OCCUPAT THERAPY,ST LOUIS,MO
[2] UNIV CALIF SAN DIEGO,DEPT ORTHOPAED,ORTHOMED PROGRAM,LA JOLLA,CA
[3] CANADIAN BACK INST,TORONTO,ON,CANADA
[4] CHART REHABIL HAWAII,HONOLULU,HI
关键词
BACK INJURY; FUNCTIONAL CAPACITY EVALUATION; LIFT TEST; TEST SAFETY; TEST DEVELOPMENT; TEST RELIABILITY;
D O I
10.1097/00007632-199510000-00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Two laboratory studies and one field study evaluated the safety and test-retest reliability of a new test of lift capacity. The first two studies were conducted in a carefully controlled laboratory setting. The first study investigated the safety and intra-rater reliability of the EPIC Lift Capacity test protocol with healthy adult subjects. The second study assessed the safety and inter-rater reliability of the test with disabled subjects. The third study was conducted in the field with 65 evaluators and investigated the safety and intra-rater reliability of the test with healthy adult subjects. Objective. To assess the safety and reliability of a new test of lift capacity. Summary of Background Data. A new test of lift capacity has been developed. Test development occurred within the context of ergonomic standards and guidelines of the major professional associations and public agencies that govern test development in the United States. Methods. In study no. 1, 26 healthy subjects participated. In study no, 2, 14 disabled subjects participated. In study no. 3,318 healthy subjects participated. After subjects underwent basic screening and warm-up, the EPIC Lift Capacity test was administered. One to 2 weeks later, the test was administered again. Correlations between the times of testing were calculated. Results, No subjects were injured. Hamstring soreness the next day that resolved without complication was reported by some healthy subjects. None of the disabled subjects reported new symptoms. Conclusion. The safety and reliability of the EPIC Lift Capacity test was adequately demonstrated in a laboratory setting and across multiple field sites with evaluators who have varying types and degrees of professional preparation.
引用
收藏
页码:2119 / 2129
页数:11
相关论文
共 79 条
[31]  
Golding L.A., Myers C.R., Sinning W.E., Eds. Y’s Way to Physical Fitness:, (1989)
[32]  
Griffin A.B., Troup J., Lloyd D., Tests of lifting and handling capacity: Their repeatability and relationship to back symptoms, Ergonomics, 27, pp. 305-320, (1984)
[33]  
Hart D.L., Isernhagen S.J., Matheson L.N., Guidelines for functional capacity evaluation of people with medical conditions, Journal of Orthopaedic and Sports Physical Therapy, 18, pp. 682-686, (1993)
[34]  
Herrin G.D., Jariedi M., Erson C.K., Prediction of overexertion injuries using biomechanical and psychophysical models, Am Ind Hyg Assoc J, 47, pp. 322-330, (1986)
[35]  
Jacobs I., Bell D.G., Pope J., Comparison of isokinetic and isoinertial lifting tests as predictors of maximal lifting capacity, Eur J Appl Physiol, 57, pp. 146-153, (1988)
[36]  
Jiang B.C., Smith J.L., Ayoub M.M., Psychophysical modeling of manual materials-handling capacities using isoinertial strength variables, Hum Factors, 28, pp. 691-702, (1986)
[37]  
Jones L.A., Hunter I.W., The relation of muscle force and EMG to perceived force in human finger flexors, Eur J Appl Physiol, 50, pp. 125-131, (1982)
[38]  
Karwowski W., Shumate C., Yates J.W., Pongpatana N., Discriminability of load heaviness: Implications for the psychophysical approach to manual lifting, Ergonomics, 35, pp. 729-744, (1992)
[39]  
Karwowski W., Psychophysical acceptability and perception of load heaviness by females, Ergonomics, 34, pp. 487-496, (1991)
[40]  
Keyserling W.M., Herrin G.D., Chaffin D.B., Isometric strength testing as a means of controlling medical incidents on strenuous jobs, J Occup Med, 22, pp. 332-336, (1980)