A TEST TO MEASURE LIFT CAPACITY OF PHYSICALLY IMPAIRED ADULTS .1. DEVELOPMENT AND RELIABILITY TESTING

被引:40
作者
MATHESON, LN
MOONEY, V
GRANT, JE
AFFLECK, M
HALL, H
MELLES, T
LICHTER, RL
MCINTOSH, G
机构
[1] UNIV WASHINGTON,SCH MED,PROGRAM OCCUPAT THERAPY,ST LOUIS,MO
[2] UNIV CALIF SAN DIEGO,DEPT ORTHOPAED,ORTHOMED PROGRAM,LA JOLLA,CA
[3] CANADIAN BACK INST,TORONTO,ON,CANADA
[4] CHART REHABIL HAWAII,HONOLULU,HI
关键词
BACK INJURY; FUNCTIONAL CAPACITY EVALUATION; LIFT TEST; TEST SAFETY; TEST DEVELOPMENT; TEST RELIABILITY;
D O I
10.1097/00007632-199510000-00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Two laboratory studies and one field study evaluated the safety and test-retest reliability of a new test of lift capacity. The first two studies were conducted in a carefully controlled laboratory setting. The first study investigated the safety and intra-rater reliability of the EPIC Lift Capacity test protocol with healthy adult subjects. The second study assessed the safety and inter-rater reliability of the test with disabled subjects. The third study was conducted in the field with 65 evaluators and investigated the safety and intra-rater reliability of the test with healthy adult subjects. Objective. To assess the safety and reliability of a new test of lift capacity. Summary of Background Data. A new test of lift capacity has been developed. Test development occurred within the context of ergonomic standards and guidelines of the major professional associations and public agencies that govern test development in the United States. Methods. In study no. 1, 26 healthy subjects participated. In study no, 2, 14 disabled subjects participated. In study no. 3,318 healthy subjects participated. After subjects underwent basic screening and warm-up, the EPIC Lift Capacity test was administered. One to 2 weeks later, the test was administered again. Correlations between the times of testing were calculated. Results, No subjects were injured. Hamstring soreness the next day that resolved without complication was reported by some healthy subjects. None of the disabled subjects reported new symptoms. Conclusion. The safety and reliability of the EPIC Lift Capacity test was adequately demonstrated in a laboratory setting and across multiple field sites with evaluators who have varying types and degrees of professional preparation.
引用
收藏
页码:2119 / 2129
页数:11
相关论文
共 79 条
[41]  
Khalil T.M., Waly S.M., Genaidy A.M., Et al., Determination of lifting abilities: A comparative study of four techniques, Am Ind Hyg Assoc J, 48, pp. 951-956, (1987)
[42]  
Kroemer K., An isoinertial technique to assess individual lifting capability, Hum Factors, 25, pp. 493-506, (1983)
[43]  
Kroemer K., Testing individual capability to lift material: Repeatability of a dynamic test compared with static testing, Journal of Safety Research, 16, pp. 1-7, (1985)
[44]  
Kumar S., Mital A., Margin of safety for the human back: A probable consensus based on published studies, Ergonomics, 35, pp. 769-781, (1992)
[45]  
Lehmann G., Physiological measurements as a basis of work organization in industry, Ergonomics, 1, pp. 328-344, (1958)
[46]  
Leskinen T., Stalhammar H.R., Rautanen M.T., Biomechanically and electromyographically assessed load on the spine in self-paced and force-paced lifting work, Ergonomics, 35, pp. 881-888, (1992)
[47]  
Magora A., Investigation of the relation between low back pain and occupation, I. Industrial Medicine, 39, pp. 465-471, (1970)
[48]  
Magora A., Investigation of the relation between low back pain and occupation, Industrial Medicine, 41, pp. 5-9, (1972)
[49]  
Matheson L., Mooney V., Caiozzo V., Et al. Effect of instructions on isokinetic trunk strength variability, reliability, absolute value, and predictive validity, Spine, 17, pp. 914-921, (1991)
[50]  
Matheson L., EPIC Lift Capacity Evaluation Manual, (1993)