CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY FOR DIRECT ANALYSIS OF CELLULAR PROTEINS

被引:110
作者
HOFSTADLER, SA
SWANEK, FD
GALE, DC
EWING, AG
SMITH, RD
机构
[1] PACIFIC NW LAB, DEPT CHEM SCI, RICHLAND, WA 99352 USA
[2] PENN STATE UNIV, DEPT CHEM, UNIVERSITY PK, PA 16802 USA
关键词
D O I
10.1021/ac00104a028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of capillary electrophoresis (CE) with electrospray ionization (ESI) mass spectrometry has proven to be broadly applicable to a wide range of biologically important compounds, When combined with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry, the combined method, in addition to high-resolution separations, affords high-resolution precision mass measurements for analytes separated from complex mixtures. Direct chemical analysis of single cells has received considerable attention in recent years; the single cell approach provides a major step toward answering important questions in the field of cellular biochemistry. In this work we present preliminary results which demonstrate the feasibility of using the CE-ESI-FTICR combination as a high-performance detection scheme for the analysis of cellular proteins acquired. directly from small populations (i.e., 5-10) of intact living cells. The human erythrocyte was chosen as a model system owing to its availability, relatively homogeneous composition, and thorough documentation of contents by previous researchers. In this work we demonstrate the on-line acquisition of high-resolution mass spectra (average resolution greater than or equal to 45 000 fwhm) of both the alpha and the beta chains of hemoglobin acquired from the injection of 10 human erythrocytes (corresponding to 4.5 fmol of hemoglobin). Given the extremely small volume of the human erythrocyte (typically 87 fL/cell), the techniques implemented here should also be adaptable to the study of larger mammalian cell systems.
引用
收藏
页码:1477 / 1480
页数:4
相关论文
共 33 条
[1]   SELECTED-ION ACCUMULATION FROM AN EXTERNAL ELECTROSPRAY-IONIZATION SOURCE WITH A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
BRUCE, JE ;
ANDERSON, GA ;
HOFSTADLER, SA ;
VANORDEN, SL ;
SHERMAN, MS ;
ROCKWOOD, AL ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :914-919
[2]   PERFORMANCE OF CARBOHYDRATE-MODIFIED FUSED-SILICA CAPILLARIES FOR THE SEPARATION OF PROTEINS BY ZONE ELECTROPHORESIS [J].
BRUIN, GJM ;
HUISDEN, R ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :339-349
[3]   QUANTITATIVE-DETERMINATION OF CATECHOLAMINES IN INDIVIDUAL BOVINE ADRENOMEDULLARY CELLS BY REVERSED-PHASE MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
COOPER, BR ;
JANKOWSKI, JA ;
LESZCZYSZYN, DJ ;
WIGHTMAN, RM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :691-694
[4]  
Curtis H., 1983, BIOLOGY
[5]   CAPILLARY ELECTROPHORESIS - METHODS AND SCOPE [J].
ENGELHARDT, H ;
BECK, W ;
KOHR, J ;
SCHMITT, T .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1993, 32 (05) :629-649
[6]  
ENNELL RB, 1974, RED BLOOD CELL
[7]  
EWING AG, 1993, J NEUROSCI METH, V48, P1872
[8]   SUSTAINED OFF-RESONANCE IRRADIATION FOR COLLISION-ACTIVATED DISSOCIATION INVOLVING FOURIER-TRANSFORM MASS-SPECTROMETRY - COLLISION-ACTIVATED DISSOCIATION TECHNIQUE THAT EMULATES INFRARED MULTIPHOTON DISSOCIATION [J].
GAUTHIER, JW ;
TRAUTMAN, TR ;
JACOBSON, DB .
ANALYTICA CHIMICA ACTA, 1991, 246 (01) :211-225
[9]   AXIAL AND RADIAL ION CLOUD COMPRESSION - COUPLING OF MAGNETRON AND CYCLOTRON MOTION TO AXIAL MOTION IN A SEGMENTED CUBIC FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE ION TRAP [J].
GUAN, SH ;
XIANG, XZ ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 124 (01) :53-67
[10]   CAPILLARY ELECTROPHORESIS FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY WITH SUSTAINED OFF-RESONANCE IRRADIATION FOR THE CHARACTERIZATION OF PROTEIN AND PEPTIDE MIXTURES [J].
HOFSTADLER, SA ;
WAHL, JH ;
BAKHTIAR, R ;
ANDERSON, GA ;
BRUCE, JE ;
SMITH, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (10) :894-899