THE APPEARANCE OF RETICULOCYTES WITH MEDIUM OR HIGH RNA-CONTENT IS A SENSITIVE INDICATOR OF BEGINNING GRANULOCYTE RECOVERY AFTER APLASIOGENIC CYTOSTATIC DRUG-THERAPY IN PATIENTS WITH AML

被引:21
作者
KUSE, R
机构
[1] Hämatologische Abteilung, Allgemeines Krankenhaus St. Georg, Hamburg 1, W-2000
关键词
RETICULOCYTES; AUTOMATIC COUNTERS; ACUTE MYELOID LEUKEMIA; BONE MARROW RECOVERY;
D O I
10.1007/BF01703238
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow-cytometric reticulocyte counts including their maturation status were performed during follow-up of induction (n = 5) and consolidation (n = 7) polychemotherapy in nine patients with acute myeloid leukemia (AML) using a Sysmex R-3000 automated counter. The reticulocytes fell to an extreme nadir (<0.01/pl) - as did leukocytes and platelets - and consisted of cells with low fluorescence ratio (LFR) only. After a median interval of 16 days, the fraction with medium fluorescence ratio (MFR) began to rise, preceding the reticulocytes with high fluorescence ratio (HFR) for a median of 1 day in all cases with partial (n = 1) or complete (n = 8) remission. At a median of 7 days after MFR and 5 days after HFR the granulocytes reached the critical limit of greater-than-or-equal-to 0.5/nl. The reticulocytes rose to the normal range after 9 and 7 days, respectively. Automated flow-cytometric reticulocyte counting including the maturation status has been shown to provide an accessible measure of erythroid activity which may be of predictive value for granulocyte recovery after aplasiogenic polychemotherapy in AML patients.
引用
收藏
页码:213 / 214
页数:2
相关论文
共 5 条
  • [1] EVALUATION OF ERYTHROPOIESIS AFTER BONE-MARROW TRANSPLANTATION - QUANTITATIVE RETICULOCYTE COUNTING
    DAVIES, SV
    CAVILL, I
    BENTLEY, N
    FEGAN, CD
    POYNTON, CH
    WHITTAKER, JA
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1992, 81 (01) : 12 - 17
  • [2] RETICULOCYTE COUNTING USING FLOW-CYTOMETRY
    NOBES, PR
    CARTER, AB
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (08) : 675 - 678
  • [3] RETICULOCYTE COUNTING IN THALASSEMIC AND OTHER CONDITIONS WITH THE R-1000 SYSMEX ANALYZER
    PATERAKIS, GS
    VOSKARIDOU, E
    LOUTRADI, A
    ROMBOS, J
    LOUKOPOULOS, D
    [J]. ANNALS OF HEMATOLOGY, 1991, 63 (04) : 218 - 222
  • [4] IDENTIFICATION OF CD71 (TRANSFERRIN RECEPTOR) EXPRESSING ERYTHROCYTES BY MULTIPARAMETER-FLOW-CYTOMETRY (MP-FCM) - CORRELATION TO THE QUANTITATION OF RETICULOCYTES AS DETERMINED BY CONVENTIONAL MICROSCOPY AND BY MP-FCM USING A RNA-STAINING DYE
    SERKE, S
    HUHN, D
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1992, 81 (03) : 432 - 439
  • [5] TSUDA I, 1989, EUR J HAEMATOL, V43, P252