BATCH AND SEMICONTINUOUS AGGREGATION AND SEDIMENTATION OF HYBRIDOMA CELLS BY ACOUSTIC-RESONANCE FIELDS

被引:65
作者
PUI, PWS
TRAMPLER, F
SONDERHOFF, SA
GROESCHL, M
KILBURN, DG
PIRET, JM
机构
[1] UNIV BRITISH COLUMBIA, BIOTECHNOL LAB, VANCOUVER, BC V6T 1Z3, CANADA
[2] UNIV BRITISH COLUMBIA, DEPT MICROBIOL & IMMUNOL, VANCOUVER, BC V6T 1Z3, CANADA
[3] UNIV BRITISH COLUMBIA, DEPT CHEM ENGN, VANCOUVER, BC V6T 1Z3, CANADA
[4] SONOSEP BIOTECH INC, RICHMOND, BC V6V 2L1, CANADA
[5] VIENNA TECH UNIV, INST GEN PHYS, A-1040 VIENNA, AUSTRIA
关键词
D O I
10.1021/bp00032a005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Ultrasound was used to enhance the sedimentation of hybridoma cells from medium in a 75 mL resonator chamber. Forces in the acoustic standing waves aggregated the cells, and the aggregates were then rapidly sedimented by gravity. Cell separation increased with acoustic treatment time and cell concentration. The separation efficiency was over 97% for cell concentrations between 10(6) and 10(7) cells/mL. During acoustic treatment at 180 W/L, the medium temperature increased at a rate of 1.3 degrees C/min. Ultrasonic exposures up to 220 W/L did not influence the viability or subsequent growth and antibody production of the cells. A decrease in cell viability was observed at a power level of 260 W/L. Batch separation efficiencies were as high as 98%. Acoustic separation was tested under semicontinuous operation, and above 90% separation efficiency was achieved at a flow rate of 0.7 L/h.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 27 条
[11]   RAPID IMMUNOASSAY TECHNIQUE FOR PROCESS MONITORING OF ANIMAL-CELL FERMENTATIONS [J].
JERVIS, E ;
KILBURN, DG .
BIOTECHNOLOGY PROGRESS, 1991, 7 (01) :28-32
[12]  
Kachel V., 1990, FLOW CYTOMETRY SORTI, V2nd, P45
[13]   ENHANCED SEDIMENTATION OF MAMMALIAN-CELLS FOLLOWING ACOUSTIC AGGREGATION [J].
KILBURN, DG ;
CLARKE, DJ ;
COAKLEY, WT ;
BARDSLEY, DW .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :559-562
[14]   GENERAL ONE-DIMENSIONAL TREATMENT OF THE LAYERED PIEZOELECTRIC RESONATOR WITH 2 ELECTRODES [J].
NOWOTNY, H ;
BENES, E .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 82 (02) :513-521
[15]   COMPARISON OF CELL PROPAGATION METHODS FOR THEIR EFFECT ON MONOCLONAL-ANTIBODY YIELD IN FERMENTERS [J].
REUVENY, S ;
VELEZ, D ;
MILLER, L ;
MACMILLAN, JD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 86 (01) :61-69
[16]  
Rooney JA, 1988, ULTRASOUND ITS CHEM, P65
[17]   A COMPUTER-CONTROLLED SYSTEM FOR THE MEASUREMENT OF COMPLETE ADMITTANCE SPECTRA OF PIEZOELECTRIC RESONATORS [J].
SCHMID, M ;
BENES, E ;
SEDLACZEK, R .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (09) :970-975
[18]  
SCHRAM CJ, 1991, ADV SONOCHEMISTRY, V2, P293
[19]   VIABLE CELL RECYCLE WITH AN INCLINED SETTLER IN THE PERFUSION CULTURE OF SUSPENDED RECOMBINANT CHINESE-HAMSTER OVARY CELLS [J].
SEARLES, JA ;
TODD, P ;
KOMPALA, DS .
BIOTECHNOLOGY PROGRESS, 1994, 10 (02) :198-206
[20]   HIGH-DENSITY CULTURE OF HYBRIDOMA CELLS USING A PERFUSION CULTURE VESSEL WITH AN EXTERNAL CENTRIFUGE [J].
TOKASHIKI, M ;
ARAI, T ;
HAMAMOTO, K ;
ISHIMARU, K .
CYTOTECHNOLOGY, 1990, 3 (03) :239-244