DETECTION OF ANTISTREPTOLYSIN O-ANTIBODY - APPLICATION OF AN INITIAL RATE METHOD OF LATEX PIEZOELECTRIC IMMUNOASSAY

被引:41
作者
MURATSUGU, M [1 ]
KUROSAWA, S [1 ]
KAMO, N [1 ]
机构
[1] HOKKAIDO UNIV,FAC PHARMACEUT SCI,DEPT BIOPHYS & PHYS CHEM,SAPPORO,HOKKAIDO 060,JAPAN
关键词
D O I
10.1021/ac00045a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Latex piezoelectric immunoassay (LPEIA is a new latex immunoassay using a piezoelectric quartz crystal (Kurosawa et al. Chem. Pharm. Bull. 1990, 38, 1117). This assay requires no immobilization of antigen or antibody on an electrode surface of a piezoelectric crystal, while the immobilization is indispensable for ordinary immunoassays using a piezoelectric crystal as a microbalance. The present paper Improves a previous method (end-point analysis) by introducing the initial rate method using a batch cell; reduction if assay volume (1.2 mL) and shortening of assay time (2-3 min) were achieved. This assay was applied to the detection antistreptolysin O antibody (ASO) in serum. The frequency change was proportional to the ASO concentration up to 1040 IU mL-1, and the method had good sensitivity tor actual clinical application. The volume of serum required for the assay was 0.02 mL. Twenty-four clinical specimens were analyzed with this LPEIA, and the values obtained were compared with those obtained with a turbidimetric latex agglutination method. The correlation coefficient between these values was 0.950 (p < 0.01).
引用
收藏
页码:2483 / 2487
页数:5
相关论文
共 43 条
  • [21] MORITA S, 1982, Patent No. 4313929
  • [22] MURAMATSU H, 1989, ANAL LETT, V22, P2155
  • [23] PIEZOELECTRIC IMMUNO SENSOR FOR THE DETECTION OF CANDIDA-ALBICANS MICROBES
    MURAMATSU, H
    KAJIWARA, K
    TAMIYA, E
    KARUBE, I
    [J]. ANALYTICA CHIMICA ACTA, 1986, 188 : 257 - 261
  • [24] COMPUTATION OF EQUIVALENT-CIRCUIT PARAMETERS OF QUARTZ CRYSTALS IN CONTACT WITH LIQUIDS AND STUDY OF LIQUID PROPERTIES
    MURAMATSU, H
    TAMIYA, E
    KARUBE, I
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2142 - 2146
  • [25] PIEZOELECTRIC CRYSTAL BIOSENSOR MODIFIED WITH PROTEIN-A FOR DETERMINATION OF IMMUNOGLOBULINS
    MURAMATSU, H
    DICKS, JM
    TAMIYA, E
    KARUBE, I
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2760 - 2763
  • [26] QUARTZ-CRYSTAL GELATION DETECTOR FOR THE DETERMINATION OF FIBRINOGEN CONCENTRATION
    MURAMATSU, H
    TAMIYA, E
    SUZUKI, M
    KARUBE, I
    [J]. ANALYTICA CHIMICA ACTA, 1989, 217 (02) : 321 - 326
  • [27] VISCOSITY MONITORING WITH A PIEZOELECTRIC QUARTZ CRYSTAL AND ITS APPLICATION TO DETERMINATION OF ENDOTOXIN BY GELATION OF LIMULUS AMEBOCYTE LYSATE
    MURAMATSU, H
    TAMIYA, E
    SUZUKI, M
    KARUBE, I
    [J]. ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) : 91 - 98
  • [28] PARATHION ANTIBODIES ON PIEZOELECTRIC-CRYSTALS
    NGEHNGWAINBI, J
    FOLEY, PH
    KUAN, SS
    GUILBAULT, GG
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1986, 108 (18) : 5444 - 5447
  • [29] OHKUNI M, 1990, NIPPONRINSHO S, P848
  • [30] DEVELOPMENT OF A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF SALMONELLA-TYPHIMURIUM
    PRUSAKSOCHACZEWSKI, E
    LUONG, JHT
    GUILBAULT, GG
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1990, 12 (03) : 173 - 177