CALIBRATION AND LONG-TERM STABILITY OF A PIXE SET-UP

被引:48
作者
JOHANSSON, GI
PALLON, J
MALMQVIST, KG
AKSELSSON, KR
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1981年 / 181卷 / 1-3期
关键词
D O I
10.1016/0029-554X(81)90585-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A general mass calibration procedure of a PIXE set-up is described. As an example, the results of the calibration of the PIXE set-up in Lund are given. For the calibration commercially available standards were used. The parameters of a physical model were adjusted to fit a calibration curve. To decrease errors due to inhomogeneities of the standard foils, the average from four different pieces of each foil was taken. The accuracy of the calibrated system in Lund is estimated to be better than 5% for individual elements and still less for ratios of adjacent elements. For long-term quality control of the results, a special sample has been designed. This consists of a thick silver plate with a small copper spot in the center. It is very sensitive to small changes in a PIXE set-up. By analyzing this sample periodically, mistakes in the arrangement are promptly detected.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 11 条
  • [1] ELIMINATION OF CHARGING IN PROTON-INDUCED X-RAY-EMISSION ANALYSIS OF INSULATING SAMPLES
    AHLBERG, M
    JOHANSSON, G
    MALMQVIST, K
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1975, 131 (02): : 377 - 379
  • [2] AKSELSSON KR, 1976, XRAY FLUORESCENCE AN, P175
  • [3] BEAM MAPPING METHOD
    AKSELSSON, R
    JOHANSSON, TB
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1971, 91 (04): : 663 - +
  • [4] X-RAY PRODUCTION BY 1.5-11 MEV PROTONS
    AKSELSSON, R
    JOHANSSON, TB
    [J]. ZEITSCHRIFT FUR PHYSIK, 1974, 266 (04): : 245 - 255
  • [5] X-RAY-FLUORESCENCE YIELDS, AUGER, AND COSTER-KRONIG TRANSITION PROBABILITIES
    BAMBYNEK, W
    SWIFT, CD
    CRASEMANN, B
    FREND, HU
    RAO, PV
    PRICE, RE
    MARK, H
    FINK, RW
    [J]. REVIEWS OF MODERN PHYSICS, 1972, 44 (04) : 716 - +
  • [6] BAUMAN SE, 1978, THESIS CITY U NEW YO
  • [7] CARLSSON LE, 1981, NUCL INSTR, V181, P539
  • [8] CHEMICAL-ANALYSIS WITH A LOW-ENERGY PARTICLE ACCELERATOR
    FINSTON, HL
    WILLIAMS, ET
    BAUMAN, SE
    JACOBSON, SH
    BOND, AH
    [J]. JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1978, 43 (02): : 523 - 539
  • [9] THIN-FILM X-RAY-FLUORESCENCE CALIBRATION STANDARDS
    HEAGNEY, JM
    HEAGNEY, JS
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 167 (01): : 137 - 138
  • [10] REX - COMPUTER-PROGRAM FOR PIXE ANALYSIS/S
    KAUFMANN, HC
    AKSELSSON, KR
    COURTNEY, WJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2): : 251 - 257