COMPARISON OF ADENOSINE, DIPYRIDAMOLE, AND DOBUTAMINE IN STRESS ECHOCARDIOGRAPHY

被引:161
作者
MARTIN, TW [1 ]
SEAWORTH, JF [1 ]
JOHNS, JP [1 ]
PUPA, LE [1 ]
CONDOS, WR [1 ]
机构
[1] BROOKE ARMY MED CTR, FT SAM HOUSTON, TX 78234 USA
关键词
ECHOCARDIOGRAPHY; DOBUTAMINE; DIPYRIDAMOLE; ADENOSINE; EXERCISE TEST;
D O I
10.7326/0003-4819-116-3-190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare adenosine, dipyridamole, and dobutamine in stress echocardiography with regard to sensitivity, specificity, accuracy, and side effects. Design: Crossover, blinded comparison, with coronary angiography serving as the criterion standard. Setting: U.S. Army tertiary care hospital. Participants: Forty participants, 25 with coronary disease and 15 without coronary disease. Patients were eligible if they had coronary angiography within 6 weeks of stress testing or if they had a risk for coronary disease of less than 5%. Measurements: Left ventricular wall motion was recorded after dobutamine (0.38 mg/kg body weight), adenosine (0.84 mg/kg body weight), and dipyridamole (0.84 mg/kg body weight) stress testing. Stress echocardiographic evaluation was considered to be abnormal if the patient developed new or progressive wall motion abnormalities. The rate of side effects for the types of echocardiography and the patient preference were recorded. Main Results: The sensitivity of dobutamine stress echocardiography (76%; 95% Cl, 59% to 93%) was significantly higher than that of adenosine echocardiography (40%; Cl, 21% to 59%; P < 0.001) and that of dipyridamole echocardiography (56%; Cl, 37% to 75%; P = 0.019). The specificity of adenosine testing (93%; Cl, 80% to 100%) was significantly higher than that of dobutamine echocardiography (60%; Cl, 35% to 85%; P = 0.008) and that of dipyridamole echocardiography (67%; Cl, 43% to 91 %; P = 0.028). Symptoms were more frequent with adenosine echocardiography (100%) than with dipyridamole (88%; P< 0.001) or dobutamine (80%; P < 0.001) echocardiography. Treatment for persistent symptoms was required in more patients after dipyridamole echocardiography (40%) than after dobutamine (12%; P < 0.001) or adenosine (0%; P < .001) echocardiography. More patients preferred dobutamine (48%) or dipyridamole (40%) echocardiography to adenosine echocardiography (12%; P < .001). Conclusions: Dobutamine stress echocardiography is more sensitive and is better tolerated than adenosine or dipyridamole stress echocardiography. Adenosine echocardiography is more specific than dobutamine or dipyridamole echocardiography and is less likely to cause persistent symptoms.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 30 条
  • [21] HIGH-DOSE DIPYRIDAMOLE ECHOCARDIOGRAPHY TEST IN EFFORT ANGINA-PECTORIS
    PICANO, E
    LATTANZI, F
    MASINI, M
    DISTANTE, A
    LABBATE, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (04) : 848 - 854
  • [22] PROGNOSTIC IMPORTANCE OF DIPYRIDAMOLE-ECHOCARDIOGRAPHY TEST IN CORONARY-ARTERY DISEASE
    PICANO, E
    SEVERI, S
    MICHELASSI, C
    LATTANZI, F
    MASINI, M
    ORSINI, E
    DISTANTE, A
    LABBATE, A
    [J]. CIRCULATION, 1989, 80 (03) : 450 - 457
  • [23] HEMODYNAMIC-ALTERATIONS DURING ISCHEMIA INDUCED BY DOBUTAMINE STRESS-TESTING
    PIERARD, LA
    BERTHE, C
    ALBERT, A
    CARLIER, J
    KULBERTUS, HE
    [J]. EUROPEAN HEART JOURNAL, 1989, 10 (09) : 783 - 790
  • [24] PREVITALI M, 1991, CIRCULATION, V83, P27
  • [25] THE SAFETY OF INTRAVENOUS DIPYRIDAMOLE THALLIUM MYOCARDIAL PERFUSION IMAGING
    RANHOSKY, A
    KEMPTHORNERAWSON, J
    [J]. CIRCULATION, 1990, 81 (04) : 1205 - 1209
  • [26] ECHOCARDIOGRAPHIC DETECTION OF CORONARY-ARTERY DISEASE DURING DOBUTAMINE INFUSION
    SAWADA, SG
    SEGAR, DS
    RYAN, T
    BROWN, SE
    DOHAN, AM
    WILLIAMS, R
    FINEBERG, NS
    ARMSTRONG, WF
    FEIGENBAUM, H
    [J]. CIRCULATION, 1991, 83 (05) : 1605 - 1614
  • [27] CONFIDENCE-INTERVALS FOR REPORTING RESULTS OF CLINICAL-TRIALS
    SIMON, R
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (03) : 429 - 435
  • [28] DIAGNOSIS OF CORONARY-ARTERY DISEASE BY CONTROLLED CORONARY VASODILATION WITH ADENOSINE AND TL-201 SCINTIGRAPHY IN PATIENTS UNABLE TO EXERCISE
    VERANI, MS
    MAHMARIAN, JJ
    HIXSON, JB
    BOYCE, TM
    STAUDACHER, RA
    [J]. CIRCULATION, 1990, 82 (01) : 80 - 87
  • [29] EFFECTS OF ADENOSINE ON HUMAN CORONARY ARTERIAL CIRCULATION
    WILSON, RF
    WYCHE, K
    CHRISTENSEN, BV
    ZIMMER, S
    LAXSON, DD
    [J]. CIRCULATION, 1990, 82 (05) : 1595 - 1606
  • [30] 1988, LANCET, V2, P1347