FACTORS AFFECTING THE IN-VIVO PRECISION OF BROAD-BAND ULTRASONIC-ATTENUATION

被引:46
作者
EVANS, WD
JONES, EA
OWEN, GM
机构
[1] Dept. of Med. Phys., Univ. Hospital of Wales, Cardiff
关键词
D O I
10.1088/0031-9155/40/1/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The in vivo precision of broad-band ultrasonic attenuation (BUA) was measured in one normal male volunteer over periods of one day and six weeks and in a group of 10 volunteers over a period of two weeks using a Walker Sonix UBA 1001 bone mineral analyser in which the foot is immersed in a water tank. Coefficients of variation ranged from 1-3% and, in general, there was no difference in BUA variance between right and left feet. However, right foot BUA values were consistently greater than those of the left, but there was no difference between mediolateral and lateromedial transmission. The use of preboiled water improved precision and reduced measurement time. In addition, factors affecting BUA precision were investigated in the individual volunteer. Equipment stability and conditions of immersion (immersion time, water depth, water temperature and concentration of a detergent wetting agent) had comparatively little effect on BUA values. On the other hand, the effects of foot positioning were more pronounced: rotation about the long axis of the foot, translation across the water tank and foot movement in the dorsal-plantar direction each contributed a maximum of 1.5-2.0% variation in BUA. However, both rotation about the long axis of the leg and foot movement in the heel-toe direction could change BUA by as much as 9%. It is likely that foot positioning will limit the precision achievable with this technique.
引用
收藏
页码:137 / 151
页数:15
相关论文
共 20 条
  • [11] A CONTACT METHOD FOR THE ASSESSMENT OF ULTRASONIC VELOCITY AND BROAD-BAND ATTENUATION IN CORTICAL AND CANCELLOUS BONE
    LANGTON, CM
    ALI, AV
    RIGGS, CM
    EVANS, GP
    BONFIELD, W
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 243 - 249
  • [12] PRELIMINARY EVALUATION OF A NEW ULTRASOUND BONE DENSITOMETER
    LEES, B
    STEVENSON, JC
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 53 (03) : 149 - 152
  • [13] BROAD-BAND ULTRASOUND ATTENUATION IN THE OS CALCIS - RELATIONSHIP TO BONE-MINERAL AT OTHER SKELETAL SITES
    MCCLOSKEY, EV
    MURRAY, SA
    MILLER, C
    CHARLESWORTH, D
    TINDALE, W
    ODOHERTY, DP
    BICKERSTAFF, DR
    HAMDY, NAT
    KANIS, JA
    [J]. CLINICAL SCIENCE, 1990, 78 (02) : 227 - 233
  • [14] BROAD-BAND ULTRASONIC-ATTENUATION IN THE OS-CALCIS AND SINGLE PHOTON-ABSORPTIOMETRY IN THE DISTAL FOREARM - A COMPARATIVE-STUDY
    POLL, V
    COOPER, C
    CAWLEY, MID
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1986, 7 (04): : 375 - 379
  • [15] COMPARISON OF SPEED OF SOUND AND ULTRASOUND ATTENUATION IN THE OS CALCIS TO BONE-DENSITY OF THE RADIUS, FEMUR AND LUMBAR SPINE
    ROSSMAN, P
    ZAGZEBSKI, J
    MESINA, C
    SORENSON, J
    MAZESS, R
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04): : 353 - 360
  • [16] ULTRASOUND MEASUREMENTS ON OS CALCIS - PRECISION AND AGE-RELATED-CHANGES IN A NORMAL FEMALE-POPULATION
    SCHOTT, AM
    HANS, D
    SORNAYRENDU, E
    DELMAS, PD
    MEUNIER, PJ
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (05) : 249 - 254
  • [17] METHODS OF BONE-MINERAL MEASUREMENT
    TOTHILL, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (05) : 543 - 572
  • [18] BONE ULTRASONIC-ATTENUATION IN WOMEN - REPRODUCIBILITY, NORMAL VARIATION AND COMPARISON WITH PHOTON-ABSORPTIOMETRY
    TRUSCOTT, JG
    SIMPSON, M
    STEWART, SP
    MILNER, R
    WESTMACOTT, CF
    OLDROYD, B
    EVANS, JA
    HORSMAN, A
    LANGTON, CM
    SMITH, MA
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01): : 29 - 36
  • [19] ULTRASOUND TRANSMISSION MEASUREMENTS THROUGH THE OS CALCIS
    ZAGZEBSKI, JA
    ROSSMAN, PJ
    MESINA, C
    MAZESS, RB
    MADSEN, EL
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (02) : 107 - 111
  • [20] [No title captured]