EFFECTS OF PHYSIOLOGICAL WAVE-FORM VARIABILITY IN TRIGGERED MR-IMAGING - THEORETICAL-ANALYSIS

被引:16
作者
LAUZON, ML
HOLDSWORTH, DW
FRAYNE, R
RUTT, BK
机构
[1] UNIV WESTERN ONTARIO, DEPT MED BIOPHYS, LONDON, ON, CANADA
[2] UNIV WESTERN ONTARIO HOSP, DEPT DIAGNOST RADIOL, LONDON N6A 5A5, ON, CANADA
[3] JOHN P ROBARTS RES INST, TOM LAWSON FAMILY IMAGING RES LABS, LONDON N6A 5K8, ON, CANADA
关键词
BLOOD; FLOW DYNAMICS; FLOW ARTIFACTS; IMAGE PROCESSING; MODEL; MATHEMATICAL; PHASE IMAGING; VASCULAR IMAGING; VELOCITY STUDIES;
D O I
10.1002/jmri.1880040618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the assumptions inherent in most forms of triggered magnetic resonance (MR) imaging is that the pulsatile waveform (be it cardiac, respiratory, or some other) is purely periodic. In reality, the periodicity condition is rarely met. Physiologic waveform variability may lead to image artifacts and errors in velocity or volume flow rate estimates. The authors analyze the effects of physiologic waveform variability in triggered MR imaging. They propose that this variability be treated as a modulation of the underlying motion waveform. This report concentrates on amplitude modulation of the velocity waveform, which results in amplitude and phase modulation of the transverse magnetization. Established Fourier and modulation theory and the recently described principles of (k, t)-space were used to derive the appearance of physiologic waveform variability artifacts in triggered MR images and to predict errors in time-averaged and instantaneous velocity estimates that may result from such motion effects, including effects such as ghost overlap. simulations and experimental results are provided to confirm the theory.
引用
收藏
页码:853 / 867
页数:15
相关论文
共 26 条
[1]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[2]  
BRACEWELL RN, 1986, FOURIER TRANSFORM IT, pCH6
[3]   VARIABILITY OF MYOCARDIAL SIGNAL ON MAGNETIC-RESONANCE IMAGES [J].
DEROOS, A ;
KUNDEL, HL ;
JOSEPH, PM ;
DOORNBOS, J ;
KRESSEL, HY .
INVESTIGATIVE RADIOLOGY, 1990, 25 (09) :1024-1028
[4]   INTERACTIVE DISPLAY OF VOLUMETRIC DATA BY FAST FOURIER PROJECTION [J].
DUNNE, S ;
NAPEL, S ;
RUTT, B .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1992, 16 (04) :237-251
[5]   COMPUTER-CONTROLLED FLOW SIMULATOR FOR MR FLOW STUDIES [J].
FRAYNE, R ;
HOLDSWORTH, DW ;
GOWMAN, LM ;
RICKEY, DW ;
DRANGOVA, M ;
FENSTER, A ;
RUTT, BK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :605-612
[6]   FREQUENCY-RESPONSE OF RETROSPECTIVELY GATED PHASE-CONTRAST MR-IMAGING - EFFECT OF INTERPOLATION [J].
FRAYNE, R ;
RUTT, BK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :907-917
[7]  
FRAYNE R, IN PRESS MAGN RESON
[8]  
GLOVER GH, 1988, MAGN RESON QUART, V4, P299
[9]  
GRADSHTEYN IS, 1980, TABLE INTEGRALS SERI, P31
[10]   ANALYSIS OF MR PHASE-CONTRAST MEASUREMENTS OF PULSATILE VELOCITY WAVE-FORMS [J].
HANGIANDREOU, NJ ;
ROSSMAN, PJ ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :387-394