FLOW-INJECTION ANALYSIS OF GLYCEROL BASED ON OXYGEN-CONSUMPTION USING GLYCEROL DEHYDROGENASE AND NADH OXIDASE

被引:8
作者
UKEDA, H
FUJITA, Y
SAWAMURA, M
KUSUNOSE, H
机构
[1] Department of Bioresources Science, Faculty of Agriculture, Kochi University, Nankoku 783
关键词
OXYGEN ELECTRODE; NADH OXIDASE; FLOW INJECTION ANALYSIS; GLYCEROL DETERMINATION;
D O I
10.2116/analsci.10.445
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis system for the determination of glycerol has been developed which incorporates a Clark-type oxygen electrode and an enzyme reactor packed with Sepharose 4B on which glycerol dehydrogenase and NADH oxidase are co-immobilized. The response of the system depended on the concentration of flavine adenine dinucleotide (FAD) added into the carrier solution [0. 1 M glycylglycine-KOH buffer (pH 9.2) containing 30 mM ammonium sulfate]. A linear relationship between the glycerol concentration and the response current in the presence of 60 muM FAD was observed over the 0.1 - 1.5 mM range. The sampling frequency was about 25 samples/h at a flow rate of 0.5 ml/min,and the relative standard deviation was 0.65% at 2.5 mM glycerol level (n=10). Application of this system to commercial white and red wines gave satisfactory results compared with the F-kit method. No sample pretreatment was necessary other than dilution.
引用
收藏
页码:445 / 448
页数:4
相关论文
共 17 条
[1]  
Amerine M. A., 1980, TECHNOLOGY WINE MAKI
[2]   BIAMPEROMETRIC DETERMINATION OF ETHANOL, LACTATE AND GLYCEROL USING IMMOBILIZED ENZYMES IN FLOW STREAMS [J].
ATTIYAT, AS ;
CHRISTIAN, GD .
ANALYST, 1980, 105 (1247) :154-160
[3]   BIAMPEROMETRIC DETERMINATION OF GLYCEROL AND TRIGLYCERIDES WITH OPEN TUBULAR CARBON ELECTRODES IN FLOW STREAMS [J].
ATTIYAT, AS ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1979, 106 (02) :225-231
[4]  
BERGMEYER HU, 1983, METHOD ENZYMAT AN, V2, P213
[5]   POTENTIOMETRIC QUANTITATION OF GLYCEROL USING IMMOBILIZED GLYCEROL DEHYDROGENASE [J].
CHEN, AK ;
STARZMANN, JA ;
LIU, CC .
BIOTECHNOLOGY AND BIOENGINEERING, 1982, 24 (04) :971-975
[6]   AUTOMATED ENZYMIC METHOD FOR DETERMINATION OF GLYCEROL [J].
GORE, MG .
ANALYTICAL BIOCHEMISTRY, 1976, 75 (02) :604-610
[7]   AUTOMATED ENZYMIC DETERMINATION OF GLYCEROL IN BEVERAGES BY AN IMMOBILIZED GLYCEROL DEHYDROGENASE NYLON-TUBE REACTOR [J].
HINSCH, W ;
ANTONIJEVIC, A ;
SUNDARAM, V .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1980, 171 (06) :449-450
[8]   DETERMINATION OF GLYCEROL, 1,2-PROPANEDIOL AND TRIGLYCERIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND A POSTCOLUMN REACTOR CONTAINING IMMOBILIZED GLYCEROL DEHYDROGENASE [J].
KIBA, N ;
GOTO, K ;
FURUSAWA, M .
ANALYTICA CHIMICA ACTA, 1986, 185 :287-294
[9]   AUTOMATED FLOW-INJECTION PROCEDURES FOR GLYCEROL AND TRIGLYCERIDES [J].
MASOOM, M ;
WORSFOLD, PJ .
ANALYTICA CHIMICA ACTA, 1986, 188 :281-283
[10]   DETERMINATION OF GLYCEROL IN WINE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH AN IMMOBILIZED GLYCEROL DEHYDROGENASE REACTOR [J].
MATSUMOTO, K ;
MATSUBARA, H ;
HAMADA, M ;
DOI, T ;
OSAJIMA, Y .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1991, 55 (04) :1055-1059