摘要
This evaluative review focused on the performance and safety of the Dutch-made Multiload copper IUD, primarily the Multiload-375 (MLCu-375) model which has a longer life expectancy (5 or more years) than the Multiload-250 (MLCu-250) model, usually cited for a life expectancy for three years. This copper-medicated IUD differs from the copper-T IUDs in shape and insertion technique. The review shows that (a) the MLCu-375 IUD seems to be slightly less effective in preventing pregnancies than TCu-380A IUD. Its efficacy is comparable to that of the Nova-T by two to three years of use; (b) the MLCu-250 IUD is similarly effective to TCu-200 but may be slightly less effective than TCu-220C; (c) no consistent differences were detectable in expulsion rates or in removal rates for bleeding/pain between the Multiload IUDs and comparative Copper-T IUDs; (d) the Multiload IUDs may perform better in nulliparous women than the T-shaped devices; (e) no or a very low incidence of uterine perforation is associated with insertions of the Multiload IUD; (f) ectopic pregnancy risks are similarly low in Multiload IUD users as in Copper-T-380A users; and (g) pelvic inflammatory disease (PID) risks are similarly low in Multiload IUD users as in users of T-shaped copper IUDs.
引用
收藏
页码:407 / 425
页数:19
相关论文
共 43 条
  • [21] RHEMREV P E R, 1985, Advances in Contraception, V1, P31, DOI 10.1007/BF01849141
  • [22] A COMPARATIVE-STUDY OF THE EASE OF REMOVAL OF INTRAUTERINE CONTRACEPTIVE DEVICES
    ROKE, CM
    [J]. CONTRACEPTION, 1988, 37 (06) : 555 - 563
  • [23] A COMPARATIVE CLINICAL-TRIAL OF THE TCU-380A, LIPPES LOOP-D AND MULTILOAD CU-375 IUDS IN INDONESIA
    SASTRAWINATA, S
    FARR, G
    PRIHADI, SM
    HUTAPEA, H
    ANWAR, M
    WAHYUDI, I
    SUNJOTO
    KEMARA, KP
    CHAMPION, CB
    ROBBINS, M
    [J]. CONTRACEPTION, 1991, 44 (02) : 141 - 154
  • [24] SAURE A, 1985, INTRAUTERINE CONTRAC, P104
  • [25] EFFECTIVENESS OF IUDS - A REVIEW
    SIVIN, I
    SCHMIDT, F
    [J]. CONTRACEPTION, 1987, 36 (01) : 55 - 84
  • [26] SIVIN I, 1991, OBSTET GYNECOL, V78, P291
  • [27] PROLONGED INTRAUTERINE CONTRACEPTION - A 7-YEAR RANDOMIZED STUDY OF THE LEVONORGESTREL 20 MCG/DAY (LNG-20) AND THE COPPER T380 AG IUDS
    SIVIN, I
    STERN, J
    COUTINHO, E
    MATTOS, CER
    ELMAHGOUB, S
    DIAZ, S
    PAVEZ, M
    ALVAREZ, F
    BRACHE, V
    THEVENIN, F
    DIAZ, J
    FAUNDES, A
    DIAZ, MM
    MCCARTHY, T
    MISHELL, DR
    SHOUPE, D
    [J]. CONTRACEPTION, 1991, 44 (05) : 473 - 480
  • [28] SIVIN I, 1985, INTRAUTERINE CONTRAC, P340
  • [29] SKJELDESTAD F E, 1987, Advances in Contraception, V3, P139, DOI 10.1007/BF01890702
  • [30] SNOWDEN R, 1982, BRIT J OBSTET GYNA S, V4, P58