FAST SPIN-ECHO MR IMAGING OF THE FEMALE PELVIS .1. USE OF A WHOLE-VOLUME COIL

被引:73
作者
SMITH, RC
REINHOLD, C
LANGE, RC
MCCAULEY, TR
KIER, R
MCCARTHY, S
机构
[1] Department of Diagnostic Imaging, Yale University, School of Medicine, New Haven, CT 06510
关键词
MAGNETIC RESONANCE (MR); PULSE SEQUENCES; PELVIC ORGANS; MR;
D O I
10.1148/radiology.184.3.1324507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this prospective study, axial and sagittal magnetic resonance (MR) images were obtained with T2-weighted conventional spin-echo (CSE) and fast spin-echo (FSE) sequences in 34 consecutive female patients who underwent clinical pelvic MR examination at 1.5 T. The MR images from each patient were compared side by side, blindly and independently, by two radiologists experienced in MR imaging who used a standardized score sheet for anatomic and pathologic findings. The FSE sequences were rated superior significantly more often than the CSE sequences in most categories of findings (P < .05), including overall image quality and reduction of motion artifact The examination time for the FSE sequences was 1 minute 46 seconds versus an examination time of 9 minutes 14 seconds for the CSE sequences. (Both CSE and FSE sequences provided 18 sections.) It is concluded that the FSE sequence provides T2-weighted anatomic and pathologic information superior to that provided by the CSE sequence and requires substantially less imaging time.
引用
收藏
页码:665 / 669
页数:5
相关论文
共 13 条
[1]   PELVIC ENDOMETRIOSIS - MR IMAGING [J].
ARRIVE, L ;
HRICAK, H ;
MARTIN, MC .
RADIOLOGY, 1989, 171 (03) :687-692
[2]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[3]   CLINICAL-APPLICATIONS AND METHODOLOGICAL DEVELOPMENTS OF THE RARE TECHNIQUE [J].
HENNIG, J ;
FRIEDBURG, H .
MAGNETIC RESONANCE IMAGING, 1988, 6 (04) :391-395
[4]   VALUE OF LIPID-SUPPRESSION AND WATER-SUPPRESSION MR IMAGES IN DISTINGUISHING BETWEEN BLOOD AND LIPID WITHIN OVARIAN MASSES [J].
KIER, R ;
SMITH, RC ;
MCCARTHY, SM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (02) :321-325
[5]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123
[6]   ADENOMYOSIS AND LEIOMYOMA - DIFFERENTIAL-DIAGNOSIS WITH MR IMAGING [J].
MARK, AS ;
HRICAK, H ;
HEINRICHS, LW ;
HENDRICKSON, MR ;
WINKLER, ML ;
BACHICA, JA ;
STICKLER, JE .
RADIOLOGY, 1987, 163 (02) :527-529
[7]   COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES [J].
MELKI, PS ;
MULKERN, RV ;
PANYCH, LP ;
JOLESZ, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :319-326
[8]   PHASE-ENCODE ORDER AND ITS EFFECT ON CONTRAST AND ARTIFACT IN SINGLE-SHOT RARE SEQUENCES [J].
MULKERN, RV ;
MELKI, PS ;
JAKAB, P ;
HIGUCHI, N ;
JOLESZ, FA .
MEDICAL PHYSICS, 1991, 18 (05) :1032-1037
[9]   CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES [J].
MULKERN, RV ;
WONG, STS ;
WINALSKI, C ;
JOLESZ, FA .
MAGNETIC RESONANCE IMAGING, 1990, 8 (05) :557-566
[10]   ENDOMETRIAL CYSTS OF THE OVARY - MR IMAGING [J].
NISHIMURA, K ;
TOGASHI, K ;
ITOH, K ;
FUJISAWA, I ;
NOMA, S ;
KAWAMURA, Y ;
NAKANO, Y ;
ITOH, H ;
TORIZUKA, K ;
OZASA, H .
RADIOLOGY, 1987, 162 (02) :315-318