DEVELOPMENT OF AN AMPEROMETRIC ASSAY FOR THE DETERMINATION OF REDUCED GLUTATHIONE, USING GLUTATHIONE-PEROXIDASE AND SCREEN-PRINTED CARBON ELECTRODES CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE

被引:46
作者
WRING, SA
HART, JP
BIRCH, BJ
机构
[1] BRISTOL POLYTECH, DEPT SCI, COLDHARBOUR LANE, BRISTOL BS16 1QY, ENGLAND
[2] SENSORS GRP, UNILEVER RES, SHARNBROOK MK44 1LQ, BEDS, ENGLAND
关键词
GLUTATHIONE PEROXIDASE; BIOSENSOR; GLUTATHIONE;
D O I
10.1002/elan.1140040307
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The systematic characterization and optimization of bovine erythrocyte glutathione peroxidase is described, together with its application in an assay employing amperometry in stirred solutions for the determination of endogenous levels of reduced glutathione (GSH). Initial studies employed UV spectroscopy, cyclic voltammetry, and amperometry in stirred solutions (to construct hydrodynamic voltammograms) for several investigations of solution conditions on the enzyme reaction rate, and reconstituted enzyme stability. Subsequently, amperometry in stirred solutions was used to monitor the enzyme-catalyzed rate of GSH oxidation and to construct calibration plots over the concentration range 10 to 50-mu-M (corresponding to normal circulating GSH levels after the envisaged sample preparation step consisting of a simple twenty fold dilution of whole blood). Enzyme selectivity studies were performed using several potential physiological interferents and selected pharmaceuticals that may be encountered in the circulation of patients being treated for rheumatoid arthritis. The coefficient of variation for the enzyme linked amperometric assay was 7.28% (n = 5) for solutions containing 40-mu-M GSH.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 31 条
[21]  
PRICE NC, 1989, FUNDAMENTALS ENZYMOL, P136
[22]   CYTOKINE-STIMULATED HUMAN-IMMUNODEFICIENCY-VIRUS REPLICATION IS INHIBITED BY N-ACETYL-L-CYSTEINE [J].
ROEDERER, M ;
STAAL, FJT ;
RAJU, PA ;
ELA, SW ;
HERZENBERG, LA ;
HERZENBERG, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (12) :4884-4888
[23]  
Tappel A L, 1978, Methods Enzymol, V52, P506
[24]  
Wendel A., 1980, ENZYMATIC BASIS DETO, P333
[25]   DEVELOPMENT OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE, FOR ELECTROCHEMICAL SENSOR APPLICATIONS [J].
WRING, SA ;
HART, JP ;
BRACEY, L ;
BIRCH, BJ .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :203-212
[26]   DEVELOPMENT OF AN IMPROVED CARBON ELECTRODE CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE AS A RE-USABLE SENSOR FOR GLUTATHIONE [J].
WRING, SA ;
HART, JP ;
BIRCH, BJ .
ANALYST, 1989, 114 (12) :1563-1570
[27]   DETERMINATION OF REDUCED GLUTATHIONE IN HUMAN WHOLE-BLOOD BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION BY A GRAPHITE-EPOXY RESIN ELECTRODE CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE [J].
WRING, SA ;
HART, JP ;
BIRCH, BJ .
TALANTA, 1991, 38 (11) :1257-1260
[28]   DETERMINATION OF GLUTATHIONE IN HUMAN-PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION WITH A CARBON-EPOXY RESIN COMPOSITE ELECTRODE CHEMICALLY MODIFIED WITH COBALT PHTHALOCYANINE [J].
WRING, SA ;
HART, JP ;
BIRCH, BJ .
ANALYST, 1989, 114 (12) :1571-1573
[29]   VOLTAMMETRIC BEHAVIOR OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH SELECTED MEDIATORS, AND THEIR APPLICATION AS SENSORS FOR THE DETERMINATION OF REDUCED GLUTATHIONE [J].
WRING, SA ;
HART, JP ;
BIRCH, BJ .
ANALYST, 1991, 116 (02) :123-129
[30]  
WYNN CH, 1979, STRUCTURE FUNCTION E, P47