COLLISIONALLY ACTIVATED DISSOCIATION AND TANDEM MASS-SPECTROMETRY OF INTACT HEMOGLOBIN BETA-CHAIN VARIANT PROTEINS WITH ELECTROSPRAY IONIZATION

被引:67
作者
LIGHTWAHL, KJ
LOO, JA
EDMONDS, CG
SMITH, RD
WITKOWSKA, HE
SHACKLETON, CHL
WU, CSC
机构
[1] PACIFIC NW LAB, DEPT CHEM SCI, RICHLAND, WA 99352 USA
[2] CHILDRENS HOSP, OAKLAND RES INST, CLIN MASS SPECTROMETRY FACIL, OAKLAND, CA 94609 USA
[3] UNIV CALIF SAN FRANCISCO, CARDIOVASC RES INST, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.1002/bms.1200220203
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrospray ionization collisionally activated dissociation (CAD) mass spectra of multiply charged human hemoglobin beta-chain variant proteins (146 amino acid residues, 15.9 kDa), generated in the atmospheric pressure/vacuum interface and in the collision quadrupole of a triple-quadrupole mass spectrometer, are shown and compared. Several series of structurally informative singly and multiply charged b- and y-mode product ions are observed, with cleavage of the Thr 50-Pro 51 CO-NH bond to produce the complementary y96 and b50 sequence ions as the most favored fragmentation pathway. The eight different beta-globin variants studied differ by a single amino acid substitution and can be differentiated from the observed m/z shifts of the assigned product ions. The overall fragmentation patterns for the variant polypeptides are very similar, with the exception of the Willamette form, in which Arg is substituted for Pro- 51, and multiply charged y96 product ions are not observed. Circular dichroism spectra of normal beta(A) and beta(Willamette) show very little difference under a variety of solvent conditions, indicating that fragmentation differences in their respective CAD mass spectra are substantially governed by primary rather than secondary structure.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 59 条
[31]   EFFECT OF REDUCING DISULFIDE-CONTAINING PROTEINS ON ELECTROSPRAY IONIZATION MASS-SPECTRA [J].
LOO, JA ;
EDMONDS, CG ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :693-698
[32]   SOLVENT-INDUCED CONFORMATIONAL-CHANGES OF POLYPEPTIDES PROBED BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
LOO, JA ;
LOO, RRO ;
UDSETH, HR ;
EDMONDS, CG ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (03) :101-105
[33]   COLLISIONAL ACTIVATION AND DISSOCIATION OF LARGE MULTIPLY CHARGED PROTEINS PRODUCED BY ELECTROSPRAY IONIZATION [J].
LOO, JA ;
EDMONDS, CG ;
UDSETH, HR ;
SMITH, RD .
ANALYTICA CHIMICA ACTA, 1990, 241 (02) :167-173
[34]   PEPTIDE AND PROTEIN-ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
LOO, JA ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) :404-412
[35]   HIGH-RESOLUTION TANDEM MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
LOO, JA ;
QUINN, JP ;
RYU, SI ;
HENRY, KD ;
SENKO, MW ;
MCLAFFERTY, FW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) :286-289
[36]  
LOO JA, IN PRESS ANAL CHEM
[37]   INFLUENCE OF PROLINE RESIDUES ON PROTEIN CONFORMATION [J].
MACARTHUR, MW ;
THORNTON, JM .
JOURNAL OF MOLECULAR BIOLOGY, 1991, 218 (02) :397-412
[38]   A COMPARISON OF KEV ATOM BOMBARDMENT MASS-SPECTRA OF PEPTIDES OBTAINED WITH A 2-SECTOR MASS-SPECTROMETER WITH THOSE FROM A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
MARTIN, SA ;
BIEMANN, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 78 :213-228
[39]  
MCLAFFERTY FW, 1983, TANDEM MASS SPECTROM
[40]   PEPTIDE SEQUENCING WITH ELECTROSPRAY IONIZATION ON A MAGNETIC-SECTOR MASS-SPECTROMETER [J].
MENG, CK ;
MCEWEN, CN ;
LARSEN, BS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (05) :151-155