3-DIMENSIONAL MYOCARDIAL DEFORMATIONS - CALCULATION WITH DISPLACEMENT FIELD FITTING TO TAGGED MR-IMAGES

被引:194
作者
ODELL, WG
MOORE, CC
HUNTER, WC
ZERHOUNI, EA
MCVEIGH, ER
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT BIOMED ENGN,BALTIMORE,MD 21205
[2] JOHNS HOPKINS UNIV,SCH MED,DEPT RADIOL,BALTIMORE,MD 21205
[3] JOHNS HOPKINS UNIV,SCH MED,MED IMAGING LAB,BALTIMORE,MD 21205
关键词
HEART; FUNCTION; MAGNETIC RESONANCE (MR); PHYSICS; MYOCARDIUM; MR;
D O I
10.1148/radiology.195.3.7754016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To reconstruct three-dimensional (3D) myocardial deformations from orthogonal sets of parallel-tagged magnetic resonance (MR) images. MATERIALS AND METHODS: Displacement information in the direction normal to the undeformed tag planes was obtained at points along tag lines. Three independent sets of one-dimensional displacement data were used to fit an analytical series expression to describe 3D displacement as a function of deformed position. The technique was demonstrated with computer-generated models of the deformed left ventricle with data from healthy human volunteers. RESULTS: Model deformations were reconstructed with a 3D tracking error of less than 0.3 mm. Error between estimated and observed one-dimensional displacements along the tags in 10 human subjects was 0.00 mm +/- 0.36 (mean +/- standard deviation). Robustness to noise in the tag displacement data was demonstrated by using a Monte Carlo simulation. CONCLUSION: The combination of rapidly acquired parallel-tagged MR images and field-fitting analysis is a valuable tool in cardiac mechanics research and in the clinical assessment of cardiac mechanical function.
引用
收藏
页码:829 / 835
页数:7
相关论文
共 26 条
  • [1] DESCRIPTION OF THE DEFORMATION OF THE LEFT-VENTRICLE BY A KINEMATIC MODEL
    ARTS, T
    HUNTER, WC
    DOUGLAS, A
    MUIJTJENS, AMM
    RENEMAN, RS
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (10) : 1119 - 1127
  • [2] OPTIMIZATION OF TAG THICKNESS FOR MEASURING POSITION WITH MAGNETIC-RESONANCE-IMAGING
    ATALAR, E
    MCVEIGH, ER
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 152 - 160
  • [3] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [4] MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION
    AXEL, L
    DOUGHERTY, L
    [J]. RADIOLOGY, 1989, 171 (03) : 841 - 845
  • [5] IMPACT OF SEMIAUTOMATED VERSUS MANUAL IMAGE SEGMENTATION ERRORS ON MYOCARDIAL STRAIN CALCULATION BY MAGNETIC-RESONANCE TAGGING
    BAZILLE, A
    GUTTMAN, MA
    MCVEIGH, ER
    ZERHOUNI, EA
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (04) : 427 - 433
  • [6] MYOCARDIAL TAGGING IN POLAR COORDINATES WITH USE OF STRIPED TAGS
    BOLSTER, BD
    MCVEIGH, ER
    ZERHOUNI, EA
    [J]. RADIOLOGY, 1990, 177 (03) : 769 - 772
  • [7] DENNEY TS, 1994, 1994 P IEEE WORKSH N
  • [8] IMPROVED MYOCARDIAL TAGGING CONTRAST
    FISCHER, SE
    MCKINNON, GC
    MAIER, SE
    BOESIGER, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 191 - 200
  • [9] TAG AND CONTOUR-DETECTION IN TAGGED MR-IMAGES OF THE LEFT-VENTRICLE
    GUTTMAN, MA
    PRINCE, JL
    MCVEIGH, ER
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 74 - 88
  • [10] LUGOLIVIERI CH, 1994, P SOC MAGNETIC RESON, P1482