摘要
Technetium-99m methoxy-isobutylisonitrile, has been shown to be a useful perfusion agent for detecting coronary artery disease. Gated acquisition of perfusion images may remove motion artefact and improve detection. We compared the results of sensitivity and specificity for detecting coronary artery disease using perfusion images from the whole cardiac cycle (ungated) or from end-diastolic (gated) frames in 46 subjects, 31 with significant coronary disease and 15 with normal coronary arteries. There was no significant difference in detection of patients with coronary disease between the ungated and end-diastolic images: 25/31 with the ungated image and 28/31 with the end-diastolic. An improvement was made in detecting defects in the left anterior descending artery territory: 17/20 with the end-diastolic vs 11/20 with the ungated image (P < 0.05) and in the right coronary artery region: 16/21 vs 10/21 (P < 0.05), with an overall improvement in detecting regions supplied by stenosed coronary arteries: 45/55 end-diastolic vs 31/55 ungated (P < 0.01). These results suggest use of the end-diastolic frame can significantly enhance the diagnostic capacity of methoxy-isobutylisonitrile perfusion imaging.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 16 条
[1]  
ALDERSON O, 1978, RADIOLOGY, V127, P531
[2]   GATED TC-99M-MIBI MYOCARDIAL-FUNCTION IMAGING [J].
AVERY, PG ;
WILLIAMS, H ;
EARLY, MY ;
HUDSON, NM ;
HUBNER, PJB .
NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (08) :677-685
[3]  
GREEN MV, 1975, J NUCL MED, V16, P95
[4]  
HAMILTON GW, 1978, J NUCL MED, V19, P1103
[5]  
KHAN JK, 1989, CIRCULATION, V79, P1282
[6]   COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS [J].
KIAT, H ;
MADDAHI, J ;
ROY, LT ;
VANTRAIN, K ;
FRIEDMAN, J ;
RESSER, K ;
BERMAN, DS .
AMERICAN HEART JOURNAL, 1989, 117 (01) :1-11
[7]  
LI QS, 1990, J NUCL MED, V31, P1069
[8]   EUROPEAN MULTICENTER COMPARISON OF TL-201 AND TC-99M METHOXYISOBUTYLISONITRILE IN ISCHEMIC-HEART-DISEASE [J].
MAISEY, MN ;
LOWRY, A ;
BISCHOFDELALOYE, A ;
FRIDRICH, R ;
INGLESE, E ;
KHALIL, MN ;
VANDERSCHOOT, JB .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (12) :869-872
[9]  
MAJEED Q, 1989, NUCL MED COMMUN, V10, P210
[10]   GATED THALLIUM SCINTIGRAPHY IN PATIENTS WITH CORONARY-ARTERY DISEASE - AN IMPROVED PLANAR IMAGING TECHNIQUE [J].
MARTIN, W ;
TWEDDEL, AC ;
MCGHIE, AI ;
HUTTON, I .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (04) :343-354