INFLUENCE OF SERUM SEPARATOR TUBES ON TOTAL AND FREE PHENYTOIN CONCENTRATIONS AND DOSAGES

被引:6
作者
CAI, WM
LEADER, WG
PORTER, WH
CHANDLER, MHH
机构
[1] UNIV KENTUCKY,COLL MED,DEPT LAB MED & PATHOL,LEXINGTON,KY 40506
[2] UNIV KENTUCKY,COLL PHARM,DIV PHARM PRACTICE & SCI,LEXINGTON,KY 40506
关键词
PHENYTOIN; SERUM SEPARATOR TUBE; DOSAGE; PHARMACOKINETICS;
D O I
10.1097/00007691-199310000-00011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The influence of serum separator tubes (SSTs) on total and free phenytoin concentrations and phenytoin dosages was evaluated in patients treated with phenytoin. Thirty blood samples were obtained from 18 patients. Equal volumes of blood were placed into SSTs and plain tubes. Samples were centrifuged, and serum analyzed for total and free phenytoin by fluorescence polarization immunoassay (FPIA) at 2, 24, and 48 h. Total phenytoin concentrations collected in SSTs were significantly lower than those collected in plain tubes at 2 (12.3 vs 12.8 mg/L, p < 0.01), 24 (11.4 vs 12.9 mg/L, p < 0.01), and 48 h (10.9 vs 12.9 mg/L, p < 0.01). These differences resulted in significantly higher calculated maximum rates of metabolism (V(max)) and daily phenytoin dosages (R0) for SSTs at 24 (V(max): 10.4 vs 10.1 mg/kg/day; R0: 8.2 vs 8.0 mg/kg/day, p < 0.01) and 48 h (V(max): 10.8 vs 10.3 mg/kg/day; R0: 8.5 vs 8.1 mg/kg/day, p < 0.01). Free phenytoin concentrations from SSTs were significantly lower at 48 h (1.56 vs 1.61 mg/L, p < 0.05). However, there were no significant differences in calculated dosages. Observed statistical differences in total phenytoin concentrations can be clinically important for making dosage adjustments, especially in patients undergoing nonlinear elimination. Thus, SSTs should not be used to collect blood for total serum phenytoin determination.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 9 条
[1]   STABILITY OF DRUG CONCENTRATIONS IN PLASMA STORED IN SERUM SEPARATOR BLOOD COLLECTION TUBES [J].
BAILEY, DN ;
COFFEE, JJ ;
BRIGGS, JR .
THERAPEUTIC DRUG MONITORING, 1988, 10 (03) :352-354
[2]  
BERGQVIST Y, 1984, CLIN CHEM, V30, P465
[3]  
CHAN KM, 1988, CLIN CHEM, V34, P2158
[4]   SUITABILITY OF COLLECTION TUBES WITH SEPARATOR GELS FOR THERAPEUTIC DRUG-MONITORING [J].
KOCH, TR ;
PLATOFF, G .
THERAPEUTIC DRUG MONITORING, 1990, 12 (03) :277-280
[5]   EFFECT OF SERUM SEPARATOR TUBES ON FREE AND TOTAL PHENYTOIN AND CARBAMAZEPINE SERUM CONCENTRATIONS [J].
MAURO, LS ;
MAURO, VF .
THERAPEUTIC DRUG MONITORING, 1991, 13 (03) :240-243
[6]   STABILITY OF PHENYTOIN IN BLOOD COLLECTED IN VACUUM BLOOD COLLECTION TUBES [J].
PARISH, RC ;
ALEXANDER, T .
THERAPEUTIC DRUG MONITORING, 1990, 12 (01) :85-89
[7]   EFFECT OF SERUM SEPARATOR BLOOD COLLECTION TUBES ON DRUG CONCENTRATIONS [J].
QUATTROCCHI, F ;
KARNES, HT ;
ROBINSON, JD ;
HENDELES, L .
THERAPEUTIC DRUG MONITORING, 1983, 5 (03) :359-362
[8]  
RHONEY DH, 1993, INT PHARM ABSTR, V30, P232
[9]  
TOZER TN, 1992, APPLIED PHARMACOKINE, P2501