ARTERIAL BLOOD-GAS ANALYSIS OR OXYGEN-SATURATION IN THE ASSESSMENT OF ACUTE ASTHMA

被引:57
作者
CARRUTHERS, DM [1 ]
HARRISON, BDW [1 ]
机构
[1] W NORWICH HOSP,DEPT RESP MED,NORWICH NR2 3TU,NORFOLK,ENGLAND
关键词
ASTHMA; OXIMETRY; ARTERIAL GASES;
D O I
10.1136/thx.50.2.186
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background - A study was undertaken to determine if arterial blood gas estimation is always necessary in the assessment of patients presenting to hospital with acute severe asthma, or whether oxygen saturation as measured by pulse oximetry is a reliable screening test for predicting those in respiratory failure. Methods - A prospective study was conducted in a specialist respiratory medical unit. Arterial blood gas tensions and pulse oximetry were measured in 89 consecutive patients admitted with acute severe asthma. Respiratory failure was defined as PaO2 <8.0 kPa or PaCO2 >6 kPa. Results - When oxygen saturation was 92% or higher (72 patients) respiratory failure was found in three (4.2%) cases. In the 82 patients with a saturation of 90% or higher six patients (7.3%) had respiratory failure. Conclusions - In the initial assessment of acute severe asthma an oxygen saturation of >92% suggests that respiratory failure is unlikely and therefore arterial blood gas measurement is unnecessary. This study is only relevant to the assessment of asthmatic patients at presentation. Other parameters of severity must be continually assessed in all asthmatic patients admitted to hospital irrespective of the initial Sao,, and blood gases measured when clinically indicated.
引用
收藏
页码:186 / 188
页数:3
相关论文
共 10 条
[1]  
[Anonymous], 1990, BMJ, V301, P797
[2]   PULSE OXIMETER PROBES - A COMPARISON BETWEEN FINGER, NOSE, EAR AND FOREHEAD PROBES UNDER CONDITIONS OF POOR PERFUSION [J].
CLAYTON, DG ;
WEBB, RK ;
RALSTON, AC ;
DUTHIE, D ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (04) :260-265
[3]   THE BENEFITS AND PITFALLS OF PULSE OXIMETRY [J].
HUTTON, P ;
CLUTTONBROCK, T .
BRITISH MEDICAL JOURNAL, 1993, 307 (6902) :457-458
[4]   ARTERIAL-BLOOD GAS TENSION IN ASTHMA [J].
MCFADDEN, ER ;
LYONS, HA .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 278 (19) :1027-+
[5]   VALUE OF PULSUS PARADOXUS IN ASSESSING ACUTE SEVERE ASTHMA [J].
PEARSON, MG ;
SPENCE, DPS ;
RYLAND, I ;
HARRISON, BDW .
BRITISH MEDICAL JOURNAL, 1993, 307 (6905) :659-659
[6]   POTENTIAL ERRORS IN PULSE OXIMETRY .1. PULSE OXIMETER EVALUATION [J].
RALSTON, AC ;
WEBB, RK ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (03) :202-206
[7]   ASSESSMENT AND MANAGEMENT OF SEVERE ASTHMA [J].
REBUCK, AS ;
READ, J .
AMERICAN JOURNAL OF MEDICINE, 1971, 51 (06) :788-&
[8]  
RUDOLF M, 1979, CLIN SCI MOL MED, V59, P389
[9]  
West JB, 1990, RESP PHYSL ESSENTIAL, P69
[10]  
1993, THORAX, V48, pS1