PRELIMINARY EXPERIENCE USING AN OPTIMIZED 3-POINT TRANSFORMATION ALGORITHM FOR SPATIAL REGISTRATION OF COORDINATE SYSTEMS - A METHOD OF NONINVASIVE LOCALIZATION USING FRAME-BASED STEREOTAXIC GUIDANCE SYSTEMS

被引:13
作者
HEILBRUN, MP
KOEHLER, S
MACDONALD, P
SIEMIONOW, V
PETERS, W
机构
[1] Computer Imaging Laboratory, Department of Neurological Surgery, Utah University School of Medicine, Salt Lake City, UT 84132
关键词
INTRACRANIAL LOCALIZATION; 3-POINT TRANSFORMATION; STEREOTAXIS;
D O I
10.3171/jns.1994.81.5.0676
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study describes the use of an optimized three-point transformation algorithm to spatially cross-register a volumetric computerized tomographic scan or magnetic resonance image data set with the coordinate system of a stereotactic frame. This algorithm was tested for accuracy using a scanned phantom in which calculated targets, using the Brown-Roberts-Wells (BRW) frame picket-fence algorithm as a standard, could be compared to physical targets measured using a BRW are and phantom. These target values were then compared to target values calculated with the optimized three-point algorithm. This method was used for target localization in 21 patients. Following this noninvasive localization method, the standard BRW stereotactic system was used for guidance. The application accuracy of this frameless localization technique was within the limits of the scan slice thickness in 16 of 21 cases, with an average error of 2.11 mm in an average scan slice thickness of 3.1 mm. Intracranial targets were successfully reached in all cases without morbidity or mortality. The algorithm can be customized to cross-register image data sets with the coordinate systems of a wide variety of stereotactic guidance systems. The method increases the convenience and flexibility of frame-based stereotactic guidance by providing a means of noninvasive localization that can be accomplished electively at a separate time from the guidance part of a stereotactic operative procedure.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 10 条
[1]   STEREOTACTIC HEAD FRAME FOR USE WITH CT BODY SCANNERS [J].
BROWN, RA .
INVESTIGATIVE RADIOLOGY, 1979, 14 (04) :300-304
[3]   STEREOTAXIC FRAME AND COMPUTER SOFTWARE FOR CT-DIRECTED NEUROSURGICAL LOCALIZATION [J].
BROWN, RA ;
ROBERTS, TS ;
OSBORN, AG .
INVESTIGATIVE RADIOLOGY, 1980, 15 (04) :308-312
[4]  
FREITS EM, 1989, IEEE, V36, P608
[5]  
GUTHRIE B, 1990, CLIN NEUROSURG, V38, P112
[6]  
HEILBRUN MP, 1985, APPL NEUROPHYSIOL, V48, P7
[7]  
HEILBRUN MP, 1988, NEUROSURGERY STATE A, V3, P251
[8]   AN INDEPENDENT APPLICATION ACCURACY EVALUATION OF STEREOTAXIC FRAME SYSTEMS [J].
MACIUNAS, RJ ;
GALLOWAY, RL ;
LATIMER, J ;
COBB, C ;
ZACCHARIAS, E ;
MOORE, A ;
MANDAVA, VR .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1992, 58 (1-4) :103-107
[9]   A FRAMELESS STEREOTAXIC INTEGRATION OF COMPUTERIZED TOMOGRAPHIC IMAGING AND THE OPERATING MICROSCOPE [J].
ROBERTS, DW ;
STROHBEHN, JW ;
HATCH, JF ;
MURRAY, W ;
KETTENBERGER, H .
JOURNAL OF NEUROSURGERY, 1986, 65 (04) :545-549
[10]   A FRAMELESS STEREOTAXIC APPROACH TO NEUROSURGICAL PLANNING BASED ON RETROSPECTIVE PATIENT-IMAGE REGISTRATION [J].
TAN, KK ;
GRZESZCZUK, R ;
LEVIN, DN ;
PELIZZARI, CA ;
CHEN, GTY ;
ERICKSON, RK ;
JOHNSON, D ;
DOHRMANN, GJ .
JOURNAL OF NEUROSURGERY, 1993, 79 (02) :296-303