Advantages of pressurization in capillary electrophoresis/electrospray ionization mass spectrometry

被引:32
作者
Hau, J [1 ]
Roberts, M [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
关键词
D O I
10.1021/ac9903050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper we present a simple interface for coupling capillary electrophoresis (CE) to mass spectrometry (MS) which can operate without significant user intervention. The use of a dedicated interface allows rapid changeover between CE/MS and liquid chromatography (LC)/MS, which is particularly important as CE and LC are often used on the same mass spectrometer, The suitability of the interface construction is illustrated on a triple quadrupole mass spectrometer and a high-resolution time-of-flight mass spectrometer with compounds such as peptides, vitamins, and carbohydrates. Separations of these compounds are also used to evaluate the robustness of the CE-MS interface under pressurized and nonpressurized modes of operation. The simultaneous application of pressure and voltage overcomes two of the major problems commonly encountered when coupling CE to MS, i.e. unreliable long-term operation and protracted analysis times due to the long separation capillaries needed to connect to the mass spectrometer, Concomitant application of high voltage and hydrostatic pressure significantly reduces analysis time without compromising the overall separation. It was observed that pressurized CE exhibits less run-to-nm-variations, leading to run-to-run repeatability better than 0.5% for migration time and below 5% for peak area with the MS as detector.
引用
收藏
页码:3977 / 3984
页数:8
相关论文
共 24 条
[11]   GEL-FILLED CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY USING A LIQUID JUNCTION ION SPRAY INTERFACE [J].
GARCIA, F ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :985-990
[12]  
Hau J., 1994, IONISATION ATMOSPHAR
[13]  
KEELY CA, 1996, Patent No. 5482608
[14]   DURABLE GOLD-COATED FUSED-SILICA CAPILLARIES FOR USE IN ELECTROSPRAY MASS-SPECTROMETRY [J].
KRIGER, MS ;
COOK, KD ;
RAMSEY, RS .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :385-389
[15]   General considerations for optimizing a capillary electrophoresis-electrospray ionization time-of-flight mass spectrometry system [J].
Lazar, IM ;
Lee, ED ;
Rockwood, AL ;
Lee, ML .
JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) :279-288
[16]   Separation of high-molecular-mass carrageenan polysaccharides by capillary electrophoresis with laser-induced fluorescence detection [J].
Roberts, MA ;
Zhong, HJ ;
Prodolliet, J ;
Goodall, DM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :353-366
[17]   Quantitative capillary electrophoresis ion spray tandem mass spectrometry determination of EDTA in human plasma and urine [J].
Sheppard, RL ;
Henion, J .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :2901-2907
[18]   Characterization of a capillary zone electrophoresis electrospray-mass spectrometry interface [J].
Siethoff, C ;
Nigge, W ;
Linscheid, M .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1357-1361
[19]  
SMITH RD, 1989, Patent No. 4842701
[20]   SHEATHLESS CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY USING 10 MU-M ID CAPILLARIES - ANALYSES OF TRYPTIC DIGESTS OF CYTOCHROME-C [J].
WAHL, JH ;
GALE, DC ;
SMITH, RD .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :217-222