AUTOMATIC PATIENT-INSTRUCTION DEVICES IN THIN-SECTION CT OF THE THORAX - IMPACT ON IMAGE QUALITY

被引:3
作者
BANKIER, AA [1 ]
FLEISCHMANN, D [1 ]
KANTENDORFER, K [1 ]
WIESMAYR, MN [1 ]
KONTRUS, M [1 ]
HUBSCH, P [1 ]
HEROLD, CJ [1 ]
机构
[1] UNIV VIENNA,DEPT PSYCHIAT,A-1090 VIENNA,AUSTRIA
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE QUALITY; TECHNOLOGY; THORAX; CT;
D O I
10.1148/radiology.196.3.7644653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To determine what influence automatic patient-instruction (API) devices have on image quality of chest computed tomographic (CT) scans and whether the qualitative outcome justifies their routine use. MATERIALS AND METHODS: Thin-collimation CT scans of two age- and sex-matched groups of 64 patients each were evaluated prospectively for the presence of breathing artifacts and for concomitant deterioration of image quality. Breathing commands in group 1 were given with the API device and in group 2 with technologist-performed patient instruction. Cardiac motion artifacts were not evaluated. The frequency of scans repeated owing to breathing artifact was determined. RESULTS: Image quality was worse in group 1 compared with that of group 2. The percentage of scans repeated was higher with API (38%) than without API (16%). CONCLUSION: API devices cannot be recommended for thin-section CT of the thorax. The large number of scans that must be repeated leads to a considerable increase in patient irradiation, scanning time, and cost.
引用
收藏
页码:841 / 844
页数:4
相关论文
共 11 条
[1]
HIGH-RESOLUTION CT OF THE LUNGS - AN OPTIMAL APPROACH [J].
MAYO, JR ;
WEBB, WR ;
GOULD, R ;
STEIN, MG ;
BASS, I ;
GAMSU, G ;
GOLDBERG, HI .
RADIOLOGY, 1987, 163 (02) :507-510
[2]
THE DOUBLE-FISSURE SIGN - A MOTION ARTIFACT ON THIN-SECTION CT SCANS [J].
MAYO, JR ;
MULLER, NL ;
HENKELMAN, RM .
RADIOLOGY, 1987, 165 (02) :580-581
[3]
CRITICAL ANALYSIS OF RADIOLOGIST-PATIENT INTERACTION [J].
MORRIS, KJ ;
TARICO, VS ;
SMITH, WL ;
ALTMAIER, EM ;
FRANKEN, EA .
RADIOLOGY, 1987, 163 (02) :565-567
[4]
ANXIETY IN PATIENTS UNDERGOING MR IMAGING [J].
QUIRK, ME ;
LETENDRE, AJ ;
CIOTTONE, RA ;
LINGLEY, JF .
RADIOLOGY, 1989, 170 (02) :463-466
[5]
EVALUATION OF 3 PSYCHOLOGIC INTERVENTIONS TO REDUCE ANXIETY DURING MR IMAGING [J].
QUIRK, ME ;
LETENDRE, AJ ;
CIOTTONE, RA ;
LINGLEY, JF .
RADIOLOGY, 1989, 173 (03) :759-762
[6]
RITCHIE CJ, 1992, P IEEE EMBS, V14, P1782
[7]
MINIMUM SCAN SPEEDS FOR SUPPRESSION OF MOTION ARTIFACTS IN CT [J].
RITCHIE, CJ ;
GODWIN, JD ;
CRAWFORD, CR ;
STANFORD, W ;
ANNO, H ;
KIM, Y .
RADIOLOGY, 1992, 185 (01) :37-42
[8]
PREDICTIVE RESPIRATORY GATING - A NEW METHOD TO REDUCE MOTION ARTIFACTS ON CT SCANS [J].
RITCHIE, CJ ;
HSIEH, J ;
GARD, MF ;
GODWIN, JD ;
KIM, YM ;
CRAWFORD, CR .
RADIOLOGY, 1994, 190 (03) :847-852
[9]
TUNING FORK ARTIFACT IN COMPUTERIZED TOMOGRAPHY [J].
SHEPP, LA ;
HILAL, SK ;
SCHULZ, RA .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1979, 10 (03) :246-255
[10]
PATIENT EXPECTATIONS OF RADIOLOGY IN NONINTERACTIVE ENCOUNTERS [J].
SMITH, WL ;
ALTMAIER, EM ;
ROSS, RR ;
JOHNSON, BD ;
BERBEROGLU, LS .
RADIOLOGY, 1989, 172 (01) :275-276