LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN THE HEAD AND NECK REGION

被引:29
作者
HURKMANS, C
KNOOS, T
NILSSON, P
SVAHNTAPPER, G
DANIELSSON, H
机构
[1] Department of Radiation Physics, University Hospital in Lund
关键词
RADIOTHERAPY; DOSE PLANNING; PENCIL BEAM ALGORITHM; HEAD AND NECK REGION; PATIENT MODELING;
D O I
10.1016/0167-8140(95)01609-K
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The inherent limitations of a specific pencil beam model have been studied when applied to a cylindrical geometry simulating the neck region. A comparison is made between measured and calculated absorbed dose in a cylindrical phantom. The goal is to quantify the deviations in the absorbed dose level, i.e., the dose per monitor unit, when photons are used for the treatment of head and neck tumours. Square fields ranging from 5 x 5 up to 30 x 30 cm(2) are studied for photon beam energies of Co-60, 4, 6 and 18 MV. Ionisation chamber measurements have been performed in the cylinder as well as in two other configurations in order to trace the origin of possible deviations. For 18 MV no significant deviations are found between measurement and calculation in the cylindrical configuration. For the lower energies, an overestimation of the calculated dose in the cylindrical configuration up to about 6% for a 20 x 20-cm(2) Co-60 field has been found. These deviations have been traced to the basic approximation for the integration volume for phantom scatter calculations inherent in this pencil beam implementation.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 15 条
[1]   ACQUISITION OF THE EFFECTIVE LATERAL ENERGY FLUENCE DISTRIBUTION FOR PHOTON-BEAM DOSE CALCULATIONS BY CONVOLUTION MODELS [J].
AHNESJO, A ;
TREPP, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :973-985
[2]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[3]   ANALYTIC MODELING OF PHOTON SCATTER FROM FLATTENING FILTERS IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1994, 21 (08) :1227-1235
[4]   APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS [J].
AHNESJO, A ;
KNOOS, T ;
MONTELIUS, A .
MEDICAL PHYSICS, 1992, 19 (02) :295-301
[5]   DETERMINATION OF EFFECTIVE BREMSSTRAHLUNG SPECTRA AND ELECTRON CONTAMINATION FOR PHOTON DOSE CALCULATIONS [J].
AHNESJO, A ;
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (10) :1451-1464
[6]  
AHNESJO A, 1994, 11TH P INT C US COMP, P282
[7]  
AHNESJO A, 1991, THESIS STOCKHOLM U
[8]  
BRAHME A, 1988, ACTA ONCOL S, V1
[9]   COMPARISON OF MEASURED AND CALCULATED ABSORBED DOSES FROM TANGENTIAL IRRADIATION OF THE BREAST [J].
KNOOS, T ;
AHLGREN, L ;
NILSSON, M .
RADIOTHERAPY AND ONCOLOGY, 1986, 7 (01) :81-88
[10]   THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM [J].
KNOOS, T ;
CEBERG, C ;
WEBER, L ;
NILSSON, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1609-1628