TRANSTELEPHONIC INTERROGATION OF THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR

被引:9
作者
ANDERSON, MH
PAUL, VE
JONES, S
WARD, DE
CAMM, AJ
机构
[1] Department of Cardiological Sciences, St. George's Hospital Medical School, London
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 08期
关键词
IMPLANTABLE DEFIBRILLATOR; TRANSTELEPHONIC INTERROGATION;
D O I
10.1111/j.1540-8159.1992.tb03117.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Third generation implantable cardioverter defibrillators (ICDs) have extensive memory capability to store data about the patient's arrhythmias and the effect of therapies delivered by the ICD. However, this data has so far been accessible only when the patient attends the pacing clinic. Two Medtronic 9421 PCD(TM) Teletrace(R) transmitters have been used to interrogate Medtronic 7216A and 7217B PCD(TM)s at distances of up to 300 miles from our hospital and transmit the data to a 9420 PCD(TM) Teletrace(R) receiver. Successful transmission of data has been obtained on 50 occasions with 100% data concordance with repeat transmission. The system can reduce the number of unscheduled clinic visits, reduce delay in making a diagnosis following unexpected delivery of a shock therapy, and reassure patients about to be discharged following ICD implantation. The benefits are magnified where patients reside far away from the implanting center.
引用
收藏
页码:1144 / 1150
页数:7
相关论文
共 9 条
[1]   TRANSTELEPHONIC MONITORING OF 25,919 IMPLANTED PACEMAKERS [J].
DREIFUS, LS ;
ZINBERG, A ;
HURZELER, P ;
PUZIAK, AD ;
PENNOCK, R ;
FELDMAN, M ;
MORSE, DP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (03) :371-378
[2]   TRANSTELEPHONIC DEFIBRILLATION [J].
FELDSTEIN, JS ;
OCONNOR, RE ;
HENRY, J ;
SIMMONS, B ;
NITOWSKI, L .
ANNALS OF EMERGENCY MEDICINE, 1990, 19 (12) :1367-1370
[3]   ACTUARIAL INCIDENCE AND PATTERN OF OCCURRENCE OF SHOCKS FOLLOWING IMPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
FOGOROS, RN ;
ELSON, JJ ;
BONNET, CA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09) :1465-1473
[4]  
GESSMAN LJ, 1991, PACE, V14, P718
[5]  
KOU W, 1991, PACE PACING CLIN E 2, V14, P721
[6]   TRANSTELEPHONIC MONITORING OF A TACHYCARDIA-TERMINATING PACEMAKER [J].
LYONS, C ;
SCHROEDER, P ;
SHANKAR, K ;
BRODINE, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (01) :34-36
[7]   THE 1981 UNITED-STATES SURVEY OF CARDIAC PACING PRACTICES [J].
PARSONNET, V ;
CRAWFORD, CC ;
BERNSTEIN, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (05) :1321-1332
[8]   A PROSPECTIVE-STUDY UTILIZING A TRANSTELEPHONIC ELECTROCARDIOGRAPHIC TRANSMISSION PROGRAM TO MANAGE PATIENTS IN THE FIRST SEVERAL MONTHS POST-ICD IMPLANT [J].
PORTERFIELD, JG ;
PORTERFIELD, LM ;
BRAY, L ;
SUGALSKI, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :308-311
[9]   CARDIAC-RHYTHM PRECIPITATING AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGE IN OUTPATIENTS AS DETECTED FROM TRANSTELEPHONIC ELECTROCARDIOGRAPHIC RECORDINGS [J].
STEINBERG, JS ;
SUGALSKI, JS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (01) :95-97