NEAR-INFRARED REFLECTANCE MEASUREMENT OF NITROGEN FECAL LOSSES

被引:14
作者
BENINI, L
CALIARI, S
BONFANTE, F
GUIDI, GC
BRENTEGANI, MT
CASTELLANI, G
SEMBENINI, C
BARDELLI, E
VANTINI, I
机构
[1] UNIV VERONA,DIV GASTROENTEROL,I-37100 VERONA,ITALY
[2] UNIV VERONA,CTR MED RIABILITATIVA VALEGGID SM,CHIM CLIN LAB,I-37100 VERONA,ITALY
关键词
D O I
10.1136/gut.33.6.749
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Chemical methods of measuring nitrogen in stools are complex, unpleasant, and therefore rarely performed. Recently, near infrared reflectance (NIRA) has been suggested for stool analysis. The aim of this study was to evaluate the possible application of this method in routine faecal nitrogen measurement. Nitrogen concentration and daily output were measured in the stools of 83 patients using NIRA and, for comparison, the Kjeldahl method. Nitrogen concentration and output ranged between 0.4-2.72 g% and 0.45-8.96 g/day respectively. Correlation coefficients (r), of 0.89 and 0.97 were found between the two methods for concentration and output respectively, and similar values were found in patients on enteral nutrition. Repeated measurements from the same stool collection, requiring only a few minutes, allowed homogenisation to be avoided. NIRA seems to be an easy, fast, and reliable alternative to chemical assays of nitrogen measurement in the management of patients with digestive disorders.
引用
收藏
页码:749 / 752
页数:4
相关论文
共 13 条
[1]  
ALPERS DH, 1989, GASTROINTESTINAL DIS, P1994
[2]   COMPARISON OF AN ELEMENTAL AND 2 POLYMERIC DIETS IN COLECTOMIZED PATIENTS WITH OR WITHOUT INTESTINAL RESECTION [J].
ANDERSSON, H ;
BOSAEUS, I ;
ELLEGARD, L ;
HALLGREN, B ;
HULTEN, L ;
MAGNUSSON, O .
CLINICAL NUTRITION, 1984, 3 (04) :183-189
[3]  
ARCHIBALD RM, 1958, STANDARD METHODS CLI, V2, P91
[4]   NEAR-INFRARED SPECTROMETRY FOR FECAL FAT MEASUREMENT - COMPARISON WITH CONVENTIONAL GRAVIMETRIC AND TITRIMETRIC METHODS [J].
BENINI, L ;
CALIARI, S ;
GUIDI, GC ;
VAONA, B ;
TALAMINI, G ;
VANTINI, I ;
SCURO, LA .
GUT, 1989, 30 (10) :1344-1347
[5]  
DIMAGNO EP, 1986, EXOCRINE PANCREAS, P541
[6]  
FAIRFULLSMITH R, 1980, ANN SURG, V192, P600, DOI 10.1097/00000658-198019250-00003
[7]   ASSESSMENT OF AN AUTOMATED CHEMI-LUMINESCENCE NITROGEN ANALYZER FOR ROUTINE USE IN CLINICAL NUTRITION [J].
GRIMBLE, GK ;
WEST, MFE ;
ACUTI, ABC ;
REES, RG ;
HUNJAN, MK ;
WEBSTER, JD ;
FROST, PG ;
SILK, DBA .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (01) :100-106
[8]   EFFECT OF REPACK ON CALIBRATIONS PRODUCED FOR NEAR-INFRARED REFLECTANCE ANALYSIS [J].
MARK, H ;
WORKMAN, J .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1454-1459
[9]  
PEUCHANT E, 1988, CLIN CHEM, V34, P5
[10]   INFLUENCE OF ENERGY AND NITROGEN CONTENTS OF ENTERAL DIETS ON NITROGEN-BALANCE - A DOUBLE-BLIND PROSPECTIVE CONTROLLED CLINICAL-TRIAL [J].
REES, RGP ;
COOPER, TM ;
BEETHAM, R ;
FROST, PG ;
SILK, DBA .
GUT, 1989, 30 (01) :123-129