CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION ION-TRAP MASS-SPECTROMETRY USING A SHEATHLESS INTERFACE

被引:39
作者
RAMSEY, RS
MCLUCKEY, SA
机构
[1] Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee
关键词
MASS SPECTROMETRY; ONLINE CAPILLARY ELECTROPHORESIS; MS/MS ANALYSIS; SHEATHLESS ELECTROSPRAY SOURCE; PEPTIDES;
D O I
10.1002/mcs.1220070505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity that can be obtained with the quadrupole ion trap for on-line CE analysis using a sheathless electrospray interface and gold-tipped columns is examined. Capillaries of different i.d. are compared in continuous infusion experiments and the effects of sheath solvents on the signal for some peptides and proteins are illustrated. The sheathless CE/ITMS system using 20 mu m i.d. columns is shown to provide mid-attomole detection levels for leucine enkephalin in total ion electropherograms under full scan conditions. Good quality MS/MS spectra are also obtained for low femtomole injections of this peptide. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:461 / 469
页数:9
相关论文
共 28 条
[1]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[2]  
DOHMEIER DM, 1992, 4TH INT C HIGH PERF
[3]   LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY [J].
FORET, F ;
THOMPSON, TJ ;
VOUROS, P ;
KARGER, BL ;
GEBAUER, P ;
BOCEK, P .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4450-4458
[4]   ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :3-12
[5]  
FORET F, 1990, J MICROCOLUMN SEP, V2, P299
[6]   SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES [J].
GALE, DC ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) :1017-1021
[7]   REDUCED ELUTION SPEED DETECTION FOR CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
GOODLETT, DR ;
WAHL, JH ;
UDSETH, HR ;
SMITH, RD .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (01) :57-62
[8]   QUANTITATIVE CAPILLARY ELECTROPHORESIS ION SPRAY MASS-SPECTROMETRY ON A BENCHTOP ION-TRAP FOR THE DETERMINATION OF ISOQUINOLINE ALKALOIDS [J].
HENION, JD ;
NLORDEHAI, AV ;
CAI, JY .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2103-2109
[9]   ONLINE COUPLING OF CAPILLARY ISOTACHOPHORESIS WITH CAPILLARY ZONE ELECTROPHORESIS [J].
KANIANSKY, D ;
MARAK, J .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :191-204
[10]   DURABLE GOLD-COATED FUSED-SILICA CAPILLARIES FOR USE IN ELECTROSPRAY MASS-SPECTROMETRY [J].
KRIGER, MS ;
COOK, KD ;
RAMSEY, RS .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :385-389