BACKSCATTERING AND TRANSMISSION THROUGH A HIGH-Z INTERFACE AS A MEASURE OF ELECTRON-BEAM ENERGY

被引:7
作者
DAS, IJ [1 ]
BUSHE, HS [1 ]
机构
[1] UNIV MASSACHUSETTS, MED CTR, DEPT RADIAT ONCOL, WORCESTER, MA 01655 USA
关键词
INTERFACE DOSIMETRY; ELECTRON BEAM; BACKSCATTER; TRANSMISSION; BEAM ENERGY; QUALITY ASSURANCE;
D O I
10.1118/1.597375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ratio of electron beam transmission (Tr) and backscattering (Bs) is used as a measure of beam energy. With a proper thickness of high Z medium placed at the surface of a low Z homogeneous medium, it is observed that the function log(Tr/Bs) is a linear function of electron energy. This method is applied to electrons produced with scattering foil and pulse-Swept (scanned) beams for the nominal energies ranging from 6 to 20 MeV. This technique provides a unique alternative method which is easy, simple, and accurate within +/-3% for estimation of electron beam energy.
引用
收藏
页码:315 / 319
页数:5
相关论文
共 24 条
[11]   FIELD SHAPING IN ELECTRON-BEAM THERAPY [J].
KHAN, FM ;
MOORE, VC ;
LEVITT, SH .
BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (586) :883-886
[12]   CLINICAL ELECTRON-BEAM DOSIMETRY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-25 [J].
KHAN, FM ;
DOPPKE, KP ;
HOGSTROM, KR ;
KUTCHER, GJ ;
NATH, R ;
PRASAD, SC ;
PURDY, JA ;
ROZENFELD, M ;
WERNER, BL .
MEDICAL PHYSICS, 1991, 18 (01) :73-109
[13]   BACKSCATTERING IN ELECTRON-BEAM THERAPY FOR ENERGIES BETWEEN 3 AND 35 MEV [J].
KLEVENHAGEN, SC ;
LAMBERT, GD ;
ARBABI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (03) :363-373
[14]   PARAMETRIZATION OF DEPTH DOSE FOR ELECTRON-BEAMS [J].
MEIGOONI, AS ;
DAS, IJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :761-768
[15]   DEMONSTRATION OF RELATIVELY NEW ELECTRON DOSIMETRY MEASUREMENT TECHNIQUES ON THE MEVATRON-80 [J].
MEYER, JA ;
PALTA, JR ;
HOGSTROM, KR .
MEDICAL PHYSICS, 1984, 11 (05) :670-677
[16]   QUALITY ASSURANCE OF ELECTRON-BEAM ENERGY USING AN ALUMINUM WEDGE [J].
MOYER, RF .
RADIOLOGY, 1981, 140 (01) :237-239
[17]   A RAPID METHOD FOR ELECTRON-BEAM ENERGY CHECK [J].
PISCIOTTA, VJ ;
WU, XD ;
FIEDLER, JA ;
SERAGO, CF ;
CALISHWATZICH, ML ;
SCHWADE, JG ;
HOUDEK, PV .
MEDICAL PHYSICS, 1992, 19 (06) :1451-1453
[18]   A DEVICE FOR CHECKING ELECTRON ENERGIES [J].
PROCTER, NM .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (06) :739-743
[19]   TESTS OF AN ELECTRON MONITOR FOR ROUTINE QUALITY-CONTROL MEASUREMENTS OF ELECTRON ENERGIES [J].
RAMSAY, EB ;
REINSTEIN, LE ;
MEEK, AG .
MEDICAL PHYSICS, 1991, 18 (06) :1247-1250
[20]   ENERGY CONSTANCY CHECKING FOR ELECTRON-BEAMS USING A WEDGE-SHAPED SOLID PHANTOM COMBINED WITH A BEAM PROFILE SCANNER [J].
ROSENOW, UF ;
ISLAM, MK ;
GABALLA, H ;
RASHID, H .
MEDICAL PHYSICS, 1991, 18 (01) :19-25