BLINDED COMPARISON OF BIOPSY NEEDLES AND AUTOMATED DEVICES IN-VITRO .1. BIOPSY OF DIFFUSE HEPATIC-DISEASE

被引:35
作者
HOPPER, KD
ABENDROTH, CS
STURTZ, KW
MATTHEWS, YL
SHIRK, SJ
STEVENS, LA
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT PATHOL,HERSHEY,PA 17033
[2] PENN STATE UNIV,MILTON S HERSHEY MED CTR,INST BIOSTAT & EPIDEMIOL,HERSHEY,PA 17033
关键词
D O I
10.2214/ajr.161.6.8249745
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare several of the commonly used needles with several of the new automated biopsy devices (biopsy guns) for biopsy of diffuse hepatic disease. MATERIALS AND METHODS. Nine different biopsy needles or automated devices were each used to do three biopsies of 10 cadaveric livers. The specimens were reviewed in a blinded fashion by a pathologist who did not know which needle or device was used, and they were compared on the basis of a previously published histopathologic grading scale. RESULTS. The three conventional biopsy needles (16-gauge Jamshidi, 18-gauge Sure-Cut, and 14-gauge Tru-Cut) obtained a large amount of tissue with an average of 4.1 intact portal triads per biopsy. The 18-gauge Biopty gun obtained equivalent results. The 18-gauge Autovac gun with a 2-cm biopsy depth did not obtain any tissue in 18.5% of attempts. The 14- and 16-gauge Biopty guns and the 18-gauge Autovac gun with a 4-cm biopsy depth performed best with respect to fragment size and number of intact portal triads. CONCLUSION. Automated biopsy devices can provide more diagnostic specimens than can manual or conventional needles in bio s for diffuse hepatic disease.
引用
收藏
页码:1293 / 1297
页数:5
相关论文
共 14 条
  • [1] BABB RR, 1989, WESTERN J MED, V150, P39
  • [2] LIVER-TRANSPLANT BIOPSIES WITH A BIOPSY GUN
    CHEZMAR, JL
    KEITH, LL
    NELSON, RC
    PLAIRE, JC
    HERTZLER, GL
    BERNARDINO, ME
    [J]. RADIOLOGY, 1991, 179 (02) : 447 - 448
  • [3] AUTOMATED BIOPSY DEVICES - A BLINDED EVALUATION
    HOPPER, KD
    ABENDROTH, CS
    STURTZ, KW
    MATTHEWS, YL
    STEVENS, LA
    SHIRK, SJ
    [J]. RADIOLOGY, 1993, 187 (03) : 653 - 660
  • [4] FINE-NEEDLE ASPIRATION BIOPSY FOR CYTOPATHOLOGIC ANALYSIS - UTILITY OF SYRINGE HANDLES, AUTOMATED GUNS, AND THE NONSUCTION METHOD
    HOPPER, KD
    ABENDROTH, CS
    STURTZ, KW
    MATTHEWS, YL
    SHIRK, SJ
    [J]. RADIOLOGY, 1992, 185 (03) : 819 - 824
  • [5] HOPPER KD, 1990, RADIOLOGY, V176, P661
  • [6] ISHAK K, 1987, DISEASES LIVER, P399
  • [7] A 21-YEAR EXPERIENCE WITH MAJOR HEMORRHAGE AFTER PERCUTANEOUS LIVER-BIOPSY
    MCGILL, DB
    RAKELA, J
    ZINSMEISTER, AR
    OTT, BJ
    [J]. GASTROENTEROLOGY, 1990, 99 (05) : 1396 - 1400
  • [8] EVALUATION AND COMPARISON OF AUTOMATED BIOPSY DEVICES - WORK IN PROGRESS
    MLADINICH, CRJ
    ACKERMAN, N
    BERRY, CR
    BUERGELT, CD
    LONGMATE, J
    [J]. RADIOLOGY, 1992, 184 (03) : 845 - 847
  • [9] IMAGE-DIRECTED PERCUTANEOUS BIOPSIES WITH A BIOPSY GUN
    PARKER, SH
    HOPPER, KD
    YAKES, WF
    GIBSON, MD
    OWNBEY, JL
    CARTER, TE
    [J]. RADIOLOGY, 1989, 171 (03) : 663 - 669
  • [10] PERRAULT J, 1978, GASTROENTEROLOGY, V74, P103