A STUDY OF THE RELATIONSHIP BETWEEN PATIENT DOSE AND SIZE IN PEDIATRIC RADIOLOGY

被引:50
作者
MARTIN, CJ [1 ]
FARQUHAR, B [1 ]
STOCKDALE, E [1 ]
MACDONALD, S [1 ]
机构
[1] ABERDEEN ROYAL HOSP NHS TRUST,ROYAL ABERDEEN CHILDRENS HOSP,ABERDEEN AB9 2ZD,SCOTLAND
关键词
D O I
10.1259/0007-1285-67-801-864
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Entrance doses and dose-area products have been measured for paediatric X-ray examinations in a dedicated paediatric department. Dose-area products for barium meal and micturating cystourethrogram examinations involving fluoroscopy were substantially less than results from other studies. A number of factors contribute to this, including a high gain image intensifier used without a grid, shorter screening times, smaller numbers of films, exclusive use of a 100 mm camera and careful collimation of the X-ray field. Entrance air kerma has been measured for pelvis, abdomen, chest and skull radiographs. The relationship between dosimetric quantities and an equivalent patient diameter derived from data on patient height and weight has been studied. The results show a linear relationship between the logarithm of entrance air kerma and equivalent patient diameter for radiographic examinations performed on a single X-ray unit. Application of exponential correction factors could allow entrance doses for radiographs of children of different ages to be compared with appropriate reference doses.
引用
收藏
页码:864 / 871
页数:8
相关论文
共 16 条
[1]   RESULTS OF A SURVEY OF DOSES TO PEDIATRIC-PATIENTS UNDERGOING COMMON RADIOLOGICAL EXAMINATIONS [J].
CHAPPLE, CL ;
FAULKNER, K ;
LEE, REJ ;
HUNTER, EW .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (771) :225-231
[2]   DOSE REDUCTION BY THE USE OF ERBIUM FILTRATION IN A GENERAL RADIOGRAPHIC ROOM [J].
CRANAGE, RW ;
HOWARD, CJ ;
WELSH, AD .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (771) :232-237
[3]  
DUCK FA, 1992, PHYSICAL PROPERTIES, P239
[4]   DEPENDENCE OF THE PHOTON BACKSCATTER FACTOR FOR WATER ON SOURCE-TO-PHANTOM DISTANCE AND IRRADIATION FIELD SIZE [J].
GROSSWENDT, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1233-1245
[5]  
JONES DG, 1985, NRPB R186 NAT RAD PR
[6]   THE REFERENCE MAN IN DIAGNOSTIC-RADIOLOGY DOSIMETRY [J].
LINDSKOUG, BA .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (773) :431-437
[7]   IMPLEMENTATION OF A PROGRAM FOR REDUCTION OF RADIOGRAPHIC DOSES AND RESULTS ACHIEVED THROUGH INCREASES IN TUBE POTENTIAL [J].
MARTIN, CJ ;
DARRAGH, CL ;
MCKENZIE, GA ;
BAYLISS, AP .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (783) :228-233
[8]  
PERSLIDEN J, 1993, ACTA RADIOL, V34, P92
[9]   MEASUREMENT OF RADIATION-DOSES IN THE MOST FREQUENT SIMPLE EXAMINATIONS IN PEDIATRIC RADIOLOGY AND ITS DEPENDENCE ON PATIENT AGE [J].
RUIZ, MJ ;
GONZALEZ, L ;
VANO, E ;
MARTINEZ, A .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766) :929-933
[10]   THE INFLUENCE OF TUBE FILTRATION AND POTENTIAL ON PATIENT DOSE DURING X-RAY EXAMINATIONS [J].
SHRIMPTON, PC ;
JONES, DG ;
WALL, BF .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10) :1205-1212