OPTICAL CHARACTERISTICS OF A RUTHENIUM(II) COMPLEX IMMOBILIZED IN A SILICONE-RUBBER FILM FOR OXYGEN MEASUREMENT

被引:79
作者
LI, XM
RUAN, FC
WONG, KY
机构
关键词
OPTICAL SENSING; OXYGEN; RUTHENIUM COMPLEX; SILICONE RUBBER;
D O I
10.1039/an9931800289
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The optical characteristics of tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) perchlorate immobilized in a silicone rubber film were studied for its application to the measurement of oxygen. The luminescence intensity and the degree of quenching of the ruthenium complex by oxygen were shown to be affected by the concentration of the complex in the silicone rubber film. The optimum concentration was found to be about 0.2 mmol dm-3. At this concentration, the silicone rubber film containing the immobilized ruthenium complex emits the highest luminescence intensity and is able to undergo a high degree of quenching of the luminescence by oxygen. The quenching curves for 20 samples containing various concentrations of the ruthenium complex were correlated with high accuracy by using a modified form of the Stern-Volmer equation. The film preparation procedure and the solvent used were found to be critical for performance. The effect of the film thickness on the luminescence intensity and the dynamic response was also studied.
引用
收藏
页码:289 / 292
页数:4
相关论文
共 18 条
  • [1] DETERMINATION OF OXYGEN CONCENTRATIONS BY LUMINESCENCE QUENCHING OF A POLYMER-IMMOBILIZED TRANSITION-METAL COMPLEX
    BACON, JR
    DEMAS, JN
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2780 - 2785
  • [2] PHOTOPHYSICS AND PHOTOCHEMISTRY OF OXYGEN SENSORS BASED ON LUMINESCENT TRANSITION-METAL COMPLEXES
    CARRAWAY, ER
    DEMAS, JN
    DEGRAFF, BA
    BACON, JR
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (04) : 337 - 342
  • [3] CARRAWAY ER, 1989, THESIS U VIRGINIA
  • [4] Clark LC, 1959, Electrochemical device for chemical analysis, Patent No. [US 2913386 A, 2913386]
  • [5] OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM
    GEHRICH, JL
    LUBBERS, DW
    OPITZ, N
    HANSMANN, DR
    MILLER, WW
    TUSA, JK
    YAFUSO, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 117 - 132
  • [6] GRISHAEVA TI, 1990, ZH ANAL KHIM, V45, P1333
  • [7] LUMINESCENT BAROMETRY IN WIND TUNNELS
    KAVANDI, J
    CALLIS, J
    GOUTERMAN, M
    KHALIL, G
    WRIGHT, D
    GREEN, E
    BURNS, D
    MCLACHLAN, B
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (11) : 3340 - 3347
  • [8] A FLUORESCENCE-BASED STERILIZABLE OXYGEN PROBE FOR USE IN BIOREACTORS
    KRONEIS, HW
    MARSONER, HJ
    [J]. SENSORS AND ACTUATORS, 1983, 4 (04): : 587 - 592
  • [9] LUMINESCENT PLATINUM COMPLEX IN SOLID FILMS FOR OPTICAL SENSING OF OXYGEN
    LI, XM
    WONG, KY
    [J]. ANALYTICA CHIMICA ACTA, 1992, 262 (01) : 27 - 32
  • [10] LI XM, 1990, Patent No. 4921582