HEPATIC CT ENHANCEMENT .2. ALTERATIONS IN CONTRAST MATERIAL VOLUME AND RATE OF INJECTION WITHIN THE SAME PATIENTS

被引:69
作者
CHAMBERS, TP
BARON, RL
LUSH, RM
机构
[1] UNIV PITTSBURGH,MED CTR,DEPT RADIOL,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,MED CTR,SCH PHARM,PITTSBURGH,PA 15213
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; COMPARATIVE STUDIES; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1148/radiology.193.2.7972771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effects of alterations in contrast material volume and injection rate on liver computed tomographic (CT) enhancement within the same patients. MATERIALS AND METHODS: Forty patients underwent repeat CT within 6 months, one with 150 mL of nonionic contrast material at 2 mL/sec, the other with 150 mL. (n = 8, group A), 100 mL (n = 14, group B), or 180 mL (n = 18, group C) at 3 mL/sec. Comparisons were made only within the same patients. RESULTS: In group A, mean liver enhancement was greater with the higher rate (3 mL/sec) up to 130 seconds after injection mean peak liver enhancement was greater by 10 HU, and mean time to peak enhancement was shorter by 15 seconds. In group B, mean peak enhancement was greater with 150 mL by 9 HU, and mean time to peak enhancement was longer by 27 seconds. In group C, peak enhancement and time to peak liver enhancement were greater. CONCLUSION: Contrast material volume and injection rate have interdependent effects on liver enhancement and potentially tumor conspicuity. Higher rates compensate partially for lower volume, but enhancement is still reduced. The optimal window of time for imaging after injection varies with injection technique.
引用
收藏
页码:518 / 522
页数:5
相关论文
共 8 条
  • [1] COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY
    BERLAND, LL
    LEE, JY
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (12) : 918 - 922
  • [2] BOLTON S, 1990, PHARM STATISTICS PRA, P274
  • [3] HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    [J]. RADIOLOGY, 1994, 190 (03) : 721 - 725
  • [4] HEPATIC CT ENHANCEMENT .1. ALTERATIONS IN THE VOLUME OF CONTRAST MATERIAL WITHIN THE SAME PATIENTS
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    [J]. RADIOLOGY, 1994, 193 (02) : 513 - 517
  • [5] HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    CONFER, SR
    [J]. RADIOLOGY, 1993, 188 (03) : 627 - 631
  • [6] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [7] DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS
    HEIKEN, JP
    BRINK, JA
    MCCLENNAN, BL
    SAGEL, SS
    FORMAN, HP
    DICROCE, J
    [J]. RADIOLOGY, 1993, 187 (02) : 327 - 331
  • [8] HAND DYNAMIC INJECTION IN ELECTRON-BEAM CT SCANNING
    WINDISCH, TR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 471 - 471