THE USE OF RADIOCHROMIC FILM IN TREATMENT VERIFICATION OF DYNAMIC STEREOTAXIC RADIOSURGERY

被引:65
作者
RAMANI, R
LIGHTSTONE, AW
MASON, DLD
OBRIEN, PF
机构
[1] Toronto-Bayview Regional Cancer Ctr., 2075 Bayview Avenue, North York, Ont. M4N 3M5, Canada
关键词
RADIOCHROMIC FILM; TREATMENT VERIFICATION; STEREOTAXIC RADIOSURGERY; DOSIMETRY;
D O I
10.1118/1.597385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Standard silver-based films are usually too sensitive to be used as direct indicators of dose in dynamic radiosurgery because of optical saturation. This paper describes the use of a new radiochromic film to measure 6-MV radiosurgery doses and dose distributions in a head phantom. Dose calibration of the radiochromic film was performed in the range of 2.3-50.2 Gy using light of 632- and 530-nm wavelengths. Radiosurgery dose distributions were measured using the radiochromic film in a head phantom undergoing the same treatment as a patient, and were compared with the planned distributions. For an example case (nominal 2.0-cm-diam cone), film measurement verified the calculated dose distribution in one plane. The simple measurement technique described led to experimental uncertainties of +/- 0.1 cm for the 90% and 50% isodose lines, +/- 0.3 cm for the 20% line, and +/- 0.5 cm for the 10% line. Isocenter dose was measured with an uncertainty of +/- 3%. Refinements to the technique should allow more precise measurements. It is concluded that the radiochromic film, with some limitations, is a convenient and useful tool for dynamic radiosurgery quality assurance.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 8 条
[1]  
LEWIS DF, COMMUNICATION
[2]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[3]  
MCLAUGHLIN WL, 1992, MED PHYS, V19, P791
[4]   PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY [J].
MUENCH, PJ ;
MEIGOONI, AS ;
NATH, R ;
MCLAUGHLIN, WL .
MEDICAL PHYSICS, 1991, 18 (04) :769-775
[5]   RADIOSURGERY WITH UNFLATTENED 6-MV PHOTON BEAMS [J].
OBRIEN, PF ;
GILLIES, BA ;
SCHWARTZ, M ;
YOUNG, C ;
DAVEY, P .
MEDICAL PHYSICS, 1991, 18 (03) :519-521
[6]   DOSE DISTRIBUTIONS IN DYNAMIC STEREOTAXIC RADIOSURGERY [J].
PIKE, B ;
PODGORSAK, EB ;
PETERS, TM ;
PLA, C .
MEDICAL PHYSICS, 1987, 14 (05) :780-789
[7]  
SAYEG JA, 1992, MED PHYS, V19, P818
[8]  
1983, MED PHYS, V10, P1