INTEGRATED HIGH-T-C MULTILOOP MAGNETOMETER

被引:52
作者
LUDWIG, F
DANTSKER, E
KLEINER, R
KOELLE, D
CLARKE, J
KNAPPE, S
DRUNG, D
KOCH, H
ALFORD, NM
BUTTON, TW
机构
[1] UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV MAT SCI, BERKELEY, CA 94720 USA
[2] PHYS TECH BUNDESANSTALT, INST BERLIN, D-10587 BERLIN, GERMANY
[3] UNIV BIRMINGHAM, IRC MAT, BIRMINGHAM B15 2TT, W MIDLANDS, ENGLAND
关键词
D O I
10.1063/1.113220
中图分类号
O59 [应用物理学];
学科分类号
摘要
Two integrated, thin-film multiloop magnetometers (fractional turn SQUIDs) have been fabricated using a YBa2Cu3O7-x-SrTiO3-YBa 2Cu3O7-x multilayer process. The magnetometers have 16 parallel loops, an outer diameter of 7 mm and effective areas of 1.84 and 1.89 mm2, respectively. The magnetic field noise of the better device, measured in a YBCO tube at 77 K with a bias reversal scheme, was 37 fT Hz-1/2 at 1 Hz and 18 fT Hz-1/2 at 1 kHz.© 1995 American Institute of Physics.
引用
收藏
页码:1418 / 1420
页数:3
相关论文
共 19 条
[1]   THE PROCESSING AND PROPERTIES OF HIGH-TC THICK-FILMS [J].
BUTTON, TW ;
ALFORD, NM ;
WELLHOFER, F ;
SHIELDS, TC ;
ABELL, JS ;
DAY, M .
IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) :1434-1437
[2]  
CANTOR R, UNPUB
[3]   AN ELECTRONIC SECOND-ORDER GRADIOMETER FOR BIOMAGNETIC APPLICATIONS IN CLINICAL SHIELDED ROOMS [J].
Drung, D. ;
Koch, H. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) :2594-2597
[4]   INTEGRATED DC SQUID MAGNETOMETER WITH HIGH DV/DB [J].
DRUNG, D ;
CANTOR, R ;
PETERS, M ;
RYHANEN, T ;
KOCH, H .
IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) :3001-3004
[5]   LOW-NOISE HIGH-SPEED DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER WITH SIMPLIFIED FEEDBACK ELECTRONICS [J].
DRUNG, D ;
CANTOR, R ;
PETERS, M ;
SCHEER, HJ ;
KOCH, H .
APPLIED PHYSICS LETTERS, 1990, 57 (04) :406-408
[6]  
DRUNG D, IN PRESS J APPL PHYS
[7]   EFFECT OF THERMAL NOISE ON THE CHARACTERISTICS OF A HIGH-TC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE [J].
ENPUKU, K ;
SHIMOMURA, Y ;
KISU, T .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (11) :7929-7934
[8]   HIGHLY SENSITIVE YBA2CU3O7 DC SQUID MAGNETOMETER WITH THIN-FILM FLUX TRANSFORMER [J].
GRUNDLER, D ;
DAVID, B ;
ECKART, R ;
DOSSEL, O .
APPLIED PHYSICS LETTERS, 1993, 63 (19) :2700-2702
[9]   LOW-NOISE YBA2CU3O7-PRBA2CU3O7 MULTITURN FLUX TRANSFORMERS [J].
KEENE, MN ;
GOODYEAR, SW ;
CHEW, NG ;
HUMPHREYS, RG ;
SATCHELL, JS ;
EDWARDS, JA ;
LANDER, K .
APPLIED PHYSICS LETTERS, 1994, 64 (03) :366-368
[10]   A 37 CHANNEL DC SQUID MAGNETOMETER SYSTEM [J].
KOCH, H ;
CANTOR, R ;
DRUNG, D ;
ERNE, SN ;
MATTHIES, KP ;
PETERS, M ;
RYHANEN, T ;
SCHEER, HJ ;
HAHLBOHM, HD .
IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) :2793-2796