EMERGENCY CORONARY STENTING FOR DISSECTION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - ANGIOGRAPHIC FOLLOW-UP AFTER STENTING AND AFTER REPEAT ANGIOPLASTY OF THE STENTED SEGMENT

被引:73
作者
SCHOMIG, A
KASTRATI, A
DIETZ, R
RAUCH, B
NEUMANN, FJ
KATUS, HH
BUSCH, U
机构
[1] TECH UNIV MUNICH, MED KLIN 1, W-8000 MUNICH, GERMANY
[2] UNIV HEIDELBERG, HEIDELBERG, GERMANY
关键词
D O I
10.1016/0735-1097(94)90589-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to assess the angiographic results after emergency coronary stenting and after repeat angioplasty for restenosis within the stent. Background. There is still little angiographic information about lumen renarrowing and its correlates after emergency stenting, and data with regard to the angiographic outcome of repeat angioplasty within the stent are almost nonexistent. Methods. This study was based on the quantitative evaluation of angiograms performed before and immediately after intervention and at 6 month follow up. The study included 164 of the 183 eligible patients with emergency Palmaz-Schatz stent implantation and 31 of those with restenosis within the stent who had repeat angioplasty. Results. Stenting produced an improvement in minimal lumen diameter from 0.82 +/- 0.41 to 2.76 +/- 0.47 mm (mean +/- SD) and in diameter stenosis from 74.9 +/- 11.5% to 18.3 +/- 8.1%. Elastic recoil was 0.51 +/- 0.34 mm, or 16%, At 6-month follow-up, 32.3% of the patients had restenosis (greater than or equal to 50% stenosis). Minimal lumen diameter decreased to 1.84 +/- 0.78 mm, and diameter stenosis increased to 41.7 +/- 21.0%. The degree of lumen Loss correlated significantly with the length of the original stenosis and the initial lumen gain achieved by stenting. Thirty-one patients with in stent restenosis underwent repeat angioplasty. The primary success rate was 100%, and no abrupt vessel closure was verified. Minimal lumen diameter increased from 0.85 +/- 0.35 to 2.18 +/- 0.39 mm, and diameter stenosis decreased from 69.7 +/- 12.9% to 28.6 +/- 9.4%. Elastic recoil was 0.82 +/- 0.38 mm, or 27%. At follow-up, 38.5% of the patients had restenosis. Minimal lumen diameter was reduced to 1.72 +/- 0.67 mm, and diameter stenosis increased to 42.4 +/- 18.1%. Conclusions. Angiographic results of emergency coronary stenting compare favorably with those of conventional angioplasty. In-stent balloon redilation in patients with restenosis is associated with excellent short term results and a restenosis rate not different from that reported for nonstented vessels.
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 50 条
  • [1] MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE)
    BAIM, DS
    LEVINE, MJ
    LEON, MB
    LEVINE, S
    ELLIS, SG
    SCHATZ, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) : 364 - 366
  • [2] CHANGE IN DIAMETER OF CORONARY-ARTERY SEGMENTS ADJACENT TO STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - FAILURE OF PERCENT DIAMETER STENOSIS MEASUREMENT TO REFLECT MORPHOLOGIC CHANGES INDUCED BY BALLOON DILATION
    BEATT, KJ
    LUIJTEN, HE
    DEFEYTER, PJ
    VANDENBRAND, M
    REIBER, JHC
    SERRUYS, PW
    TENKATEN, HJ
    VANES, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) : 315 - 323
  • [3] TEAR OR DISSECTION AFTER CORONARY ANGIOPLASTY - MORPHOLOGIC CORRELATES OF AN ISCHEMIC COMPLICATION
    BLACK, AJR
    NAMAY, DL
    NIEDERMAN, AL
    LEMBO, NJ
    ROUBIN, GS
    DOUGLAS, JS
    KING, SB
    [J]. CIRCULATION, 1989, 79 (05) : 1035 - 1042
  • [4] ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE
    CARROZZA, JP
    KUNTZ, RE
    LEVINE, MJ
    POMERANTZ, RM
    FISHMAN, RF
    MANSOUR, M
    GIBSON, CM
    SENERCHIA, CC
    DIVER, DJ
    SAFIAN, RD
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 328 - 337
  • [5] EMERGENCY CORONARY-BYPASS SURGERY AFTER CORONARY ANGIOPLASTY - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTES PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY REGISTRY EXPERIENCE
    COWLEY, MJ
    DORROS, G
    KELSEY, SF
    VANRADEN, M
    DETRE, KM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) : C22 - C26
  • [6] CRIPPS TR, 1991, BRIT HEART J, V66, P3
  • [7] ACUTE CORONARY-ARTERY OCCLUSION DURING AND AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - FREQUENCY, PREDICTION, CLINICAL COURSE, MANAGEMENT, AND FOLLOW-UP
    DEFEYTER, PJ
    VANDENBRAND, M
    JAARMAN, G
    VANDOMBURG, R
    SERRUYS, PW
    SURYAPRANATA, H
    [J]. CIRCULATION, 1991, 83 (03) : 927 - 936
  • [8] WIKTOR STENT IMPLANTATION IN PATIENTS WITH RESTENOSIS FOLLOWING BALLOON ANGIOPLASTY OF A NATIVE CORONARY-ARTERY
    DEJAEGERE, PP
    SERRUYS, PW
    BERTRAND, M
    WIEGAND, V
    KOBER, G
    MARQUIS, JF
    VALEIX, B
    UEBIS, R
    PIESSENS, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 598 - 602
  • [9] ANGIOGRAPHIC AND CLINICAL PREDICTORS OF ACUTE CLOSURE AFTER NATIVE VESSEL CORONARY ANGIOPLASTY
    ELLIS, SG
    ROUBIN, GS
    KING, SB
    DOUGLAS, JS
    WEINTRAUB, WS
    THOMAS, RG
    COX, WR
    [J]. CIRCULATION, 1988, 77 (02) : 372 - 379
  • [10] ARTERIAL INJURY AND THE ENIGMA OF CORONARY RESTENOSIS
    ELLIS, SG
    MULLER, DWM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 275 - 277