EMERGENCY CORONARY STENTING FOR DISSECTION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - ANGIOGRAPHIC FOLLOW-UP AFTER STENTING AND AFTER REPEAT ANGIOPLASTY OF THE STENTED SEGMENT

被引:73
作者
SCHOMIG, A
KASTRATI, A
DIETZ, R
RAUCH, B
NEUMANN, FJ
KATUS, HH
BUSCH, U
机构
[1] TECH UNIV MUNICH, MED KLIN 1, W-8000 MUNICH, GERMANY
[2] UNIV HEIDELBERG, HEIDELBERG, GERMANY
关键词
D O I
10.1016/0735-1097(94)90589-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to assess the angiographic results after emergency coronary stenting and after repeat angioplasty for restenosis within the stent. Background. There is still little angiographic information about lumen renarrowing and its correlates after emergency stenting, and data with regard to the angiographic outcome of repeat angioplasty within the stent are almost nonexistent. Methods. This study was based on the quantitative evaluation of angiograms performed before and immediately after intervention and at 6 month follow up. The study included 164 of the 183 eligible patients with emergency Palmaz-Schatz stent implantation and 31 of those with restenosis within the stent who had repeat angioplasty. Results. Stenting produced an improvement in minimal lumen diameter from 0.82 +/- 0.41 to 2.76 +/- 0.47 mm (mean +/- SD) and in diameter stenosis from 74.9 +/- 11.5% to 18.3 +/- 8.1%. Elastic recoil was 0.51 +/- 0.34 mm, or 16%, At 6-month follow-up, 32.3% of the patients had restenosis (greater than or equal to 50% stenosis). Minimal lumen diameter decreased to 1.84 +/- 0.78 mm, and diameter stenosis increased to 41.7 +/- 21.0%. The degree of lumen Loss correlated significantly with the length of the original stenosis and the initial lumen gain achieved by stenting. Thirty-one patients with in stent restenosis underwent repeat angioplasty. The primary success rate was 100%, and no abrupt vessel closure was verified. Minimal lumen diameter increased from 0.85 +/- 0.35 to 2.18 +/- 0.39 mm, and diameter stenosis decreased from 69.7 +/- 12.9% to 28.6 +/- 9.4%. Elastic recoil was 0.82 +/- 0.38 mm, or 27%. At follow-up, 38.5% of the patients had restenosis. Minimal lumen diameter was reduced to 1.72 +/- 0.67 mm, and diameter stenosis increased to 42.4 +/- 18.1%. Conclusions. Angiographic results of emergency coronary stenting compare favorably with those of conventional angioplasty. In-stent balloon redilation in patients with restenosis is associated with excellent short term results and a restenosis rate not different from that reported for nonstented vessels.
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 50 条
  • [11] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [12] FAJADET J, 1992, Journal of the American College of Cardiology, V19, p109A
  • [13] MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT
    GORDON, PC
    GIBSON, CM
    COHEN, DJ
    CARROZZA, JP
    KUNTZ, RE
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1166 - 1174
  • [14] EMERGENCY AORTOCORONARY BYPASS AFTER FAILED ANGIOPLASTY
    GREENE, MA
    GRAY, LA
    SLATER, AD
    GANZEL, BL
    MAVROUDIS, C
    [J]. ANNALS OF THORACIC SURGERY, 1991, 51 (02) : 194 - 199
  • [15] INFLUENCE OF BALLOON SIZE AND STENOSIS MORPHOLOGY ON IMMEDIATE AND DELAYED ELASTIC RECOIL AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HANET, C
    WIJNS, W
    MICHEL, X
    SCHROEDER, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) : 506 - 511
  • [16] RESULTS OF INTRACORONARY STENTS FOR MANAGEMENT OF CORONARY DISSECTION AFTER BALLOON ANGIOPLASTY
    HAUDE, M
    ERBEL, R
    STRAUB, U
    DIETZ, U
    SCHATZ, R
    MEYER, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08) : 691 - 696
  • [17] EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HERRMANN, HC
    BUCHBINDER, M
    CLEMEN, MW
    FISCHMAN, D
    GOLDBERG, S
    LEON, MB
    SCHATZ, RA
    TIERSTEIN, P
    WALKER, CM
    HIRSHFELD, JW
    [J]. CIRCULATION, 1992, 86 (03) : 812 - 819
  • [18] TIME-COURSE OF RESTENOSIS DURING THE 1ST YEAR AFTER EMERGENCY CORONARY STENTING
    KASTRATI, A
    SCHOMIG, A
    DIETZ, R
    NEUMANN, FJ
    RICHARDT, G
    [J]. CIRCULATION, 1993, 87 (05) : 1498 - 1505
  • [19] NOVEL-APPROACH TO THE ANALYSIS OF RESTENOSIS AFTER THE USE OF 3 NEW CORONARY DEVICES
    KUNTZ, RE
    SAFIAN, RD
    LEVINE, MJ
    REIS, GJ
    DIVER, DJ
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) : 1493 - 1499
  • [20] THE IMPORTANCE OF ACUTE LUMINAL DIAMETER IN DETERMINING RESTENOSIS AFTER CORONARY ATHERECTOMY OR STENTING
    KUNTZ, RE
    SAFIAN, RD
    CARROZZA, JP
    FISHMAN, RF
    MANSOUR, M
    BAIM, DS
    [J]. CIRCULATION, 1992, 86 (06) : 1827 - 1835