EMERGENCY CORONARY STENTING FOR DISSECTION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - ANGIOGRAPHIC FOLLOW-UP AFTER STENTING AND AFTER REPEAT ANGIOPLASTY OF THE STENTED SEGMENT

被引:73
作者
SCHOMIG, A
KASTRATI, A
DIETZ, R
RAUCH, B
NEUMANN, FJ
KATUS, HH
BUSCH, U
机构
[1] TECH UNIV MUNICH, MED KLIN 1, W-8000 MUNICH, GERMANY
[2] UNIV HEIDELBERG, HEIDELBERG, GERMANY
关键词
D O I
10.1016/0735-1097(94)90589-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to assess the angiographic results after emergency coronary stenting and after repeat angioplasty for restenosis within the stent. Background. There is still little angiographic information about lumen renarrowing and its correlates after emergency stenting, and data with regard to the angiographic outcome of repeat angioplasty within the stent are almost nonexistent. Methods. This study was based on the quantitative evaluation of angiograms performed before and immediately after intervention and at 6 month follow up. The study included 164 of the 183 eligible patients with emergency Palmaz-Schatz stent implantation and 31 of those with restenosis within the stent who had repeat angioplasty. Results. Stenting produced an improvement in minimal lumen diameter from 0.82 +/- 0.41 to 2.76 +/- 0.47 mm (mean +/- SD) and in diameter stenosis from 74.9 +/- 11.5% to 18.3 +/- 8.1%. Elastic recoil was 0.51 +/- 0.34 mm, or 16%, At 6-month follow-up, 32.3% of the patients had restenosis (greater than or equal to 50% stenosis). Minimal lumen diameter decreased to 1.84 +/- 0.78 mm, and diameter stenosis increased to 41.7 +/- 21.0%. The degree of lumen Loss correlated significantly with the length of the original stenosis and the initial lumen gain achieved by stenting. Thirty-one patients with in stent restenosis underwent repeat angioplasty. The primary success rate was 100%, and no abrupt vessel closure was verified. Minimal lumen diameter increased from 0.85 +/- 0.35 to 2.18 +/- 0.39 mm, and diameter stenosis decreased from 69.7 +/- 12.9% to 28.6 +/- 9.4%. Elastic recoil was 0.82 +/- 0.38 mm, or 27%. At follow-up, 38.5% of the patients had restenosis. Minimal lumen diameter was reduced to 1.72 +/- 0.67 mm, and diameter stenosis increased to 42.4 +/- 18.1%. Conclusions. Angiographic results of emergency coronary stenting compare favorably with those of conventional angioplasty. In-stent balloon redilation in patients with restenosis is associated with excellent short term results and a restenosis rate not different from that reported for nonstented vessels.
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 50 条
  • [21] GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY
    KUNTZ, RE
    GIBSON, CM
    NOBUYOSHI, M
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 15 - 25
  • [22] A PREDICTIVE METHOD FOR ESTIMATING THE LATE ANGIOGRAPHIC RESULTS OF CORONARY INTERVENTION DESPITE INCOMPLETE ASCERTAINMENT
    KUNTZ, RE
    KEANEY, KM
    SENERCHIA, C
    BAIM, DS
    [J]. CIRCULATION, 1993, 87 (03) : 815 - 830
  • [23] OUTCOME AFTER MAJOR DISSECTION DURING CORONARY ANGIOPLASTY USING THE PERFUSION BALLOON CATHETER
    LEITSCHUH, ML
    MILLS, RM
    JACOBS, AK
    RUOCCO, NA
    LAROSA, D
    FAXON, DP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (13) : 1056 - 1060
  • [24] LEON M B, 1992, Journal of the American College of Cardiology, V19, p109A
  • [25] CLINICAL AND ANGIOGRAPHIC RESULTS OF BALLOON-EXPANDABLE INTRACORONARY STENTS IN RIGHT CORONARY-ARTERY STENOSES
    LEVINE, MJ
    LEONARD, BM
    BURKE, JA
    NASH, ID
    SAFIAN, RD
    DIVER, DJ
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) : 332 - 339
  • [26] QUANTITATIVE ANGIOGRAPHIC COMPARISON OF THE IMMEDIATE SUCCESS OF CORONARY ANGIOPLASTY, CORONARY ATHERECTOMY AND ENDOLUMINAL STENTING
    MULLER, DWM
    ELLIS, SG
    DEBOWEY, DL
    TOPOL, EJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (12) : 938 - 942
  • [27] RESTENOSIS AFTER SUCCESSFUL PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - SERIAL ANGIOGRAPHIC FOLLOW-UP OF 229 PATIENTS
    NOBUYOSHI, M
    KIMURA, T
    NOSAKA, H
    MIOKA, S
    UENO, K
    YOKOI, H
    HAMASAKI, N
    HORIUCHI, H
    OHISHI, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (03) : 616 - 623
  • [28] CLINICAL-TRIALS OF RESTENOSIS AFTER CORONARY ANGIOPLASTY
    POPMA, JJ
    CALIFF, RM
    TOPOL, EJ
    [J]. CIRCULATION, 1991, 84 (03) : 1426 - 1436
  • [29] ANGIOGRAPHIC RISK-FACTORS OF LUMINAL NARROWING AFTER CORONARY BALLOON ANGIOPLASTY USING BALLOON MEASUREMENTS TO REFLECT STRETCH AND ELASTIC RECOIL AT THE DILATATION SITE
    RENSING, BJ
    HERMANS, WRM
    VOS, J
    BEATT, KJ
    BOSSUYT, P
    RUTSCH, W
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 584 - 591
  • [30] QUANTITATIVE ANGIOGRAPHIC ASSESSMENT OF ELASTIC RECOIL AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    RENSING, BJ
    HERMANS, WRM
    BEATT, KJ
    LAARMAN, GJ
    SURYAPRANATA, H
    VANDENBRAND, M
    DEFEYTER, PJ
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) : 1039 - 1044