EFFICIENT GLUCOSE DETECTION IN ANAEROBIC SOLUTIONS USING AN ENZYME-MODIFIED ELECTRODE DESIGNED TO DETECT H2O2 - IMPLICATIONS FOR BIOMEDICAL APPLICATIONS

被引:18
作者
LOWRY, JP [1 ]
MCATEER, K [1 ]
ELATRASH, SS [1 ]
ONEILL, RD [1 ]
机构
[1] NATL UNIV IRELAND UNIV COLL DUBLIN,DEPT CHEM,DUBLIN 4,IRELAND
关键词
D O I
10.1039/c39940002483
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The finding that a 'first generation' glucose oxidase modified poly(o-phenylenediamine) coated Pt electrode, designed to detect H2O2, responded to glucose in N-2-saturated solutions with a sensitivity similar to that of air-saturated media is of considerable significance for the application of biosensors in biological systems where O-2 availability is severely restricted.
引用
收藏
页码:2483 / 2484
页数:2
相关论文
共 14 条
[1]   A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1552-1559
[2]   ELECTROCHEMICAL STUDY OF D-GLUCOSE OXIDASE AUTO-INACTIVATION [J].
BOURDILLON, C ;
THOMAS, V ;
THOMAS, D .
ENZYME AND MICROBIAL TECHNOLOGY, 1982, 4 (03) :175-180
[3]   ELECTROANALYTICAL X-RAY PHOTOELECTRON-SPECTROSCOPY INVESTIGATION ON GLUCOSE-OXIDASE ADSORBED ON PLATINUM [J].
DEBENEDETTO, GE ;
MALITESTA, C ;
ZAMBONIN, CG .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (11) :1495-1499
[4]   ELECTROPOLYMERIZED O-PHENYLENEDIAMINE FILM AS MEANS OF IMMOBILISING LACTATE OXIDASE FOR A L-LACTATE BIOSENSOR [J].
DEMPSEY, E ;
WANG, J ;
SMYTH, MR .
TALANTA, 1993, 40 (03) :445-451
[5]   SURFACE MODIFICATION OF ELECTRODES FOR AMPEROMETRIC BIOSENSORS IN ANALYTICAL-CHEMISTRY [J].
DONG, SJ .
ANALYTICAL SCIENCES, 1994, 10 (01) :175-177
[6]   CHARACTERIZATION OF GLUCOSE OXIDASE-MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES IN-VITRO AND IN-VIVO - HOMOGENEOUS INTERFERENCE BY ASCORBIC-ACID IN HYDROGEN-PEROXIDE DETECTION [J].
LOWRY, JP ;
MCATEER, K ;
ELATRASH, SS ;
DUFF, A ;
ONEILL, RD .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1754-1761
[7]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[8]   PERFORMANCE OF SUBCUTANEOUSLY IMPLANTED NEEDLE-TYPE GLUCOSE SENSORS EMPLOYING A NOVEL TRILAYER COATING [J].
MOUSSY, F ;
HARRISON, DJ ;
OBRIEN, DW ;
RAJOTTE, RV .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2072-2077
[10]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117