EVALUATION OF PEROXYOXALATE CHEMILUMINESCENCE FOR THE SENSITIVE DETERMINATION OF HALLUCINOGENIC ALKALOIDS

被引:12
作者
CEPAS, J [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
CHEMILUMINESCENCE; PEROXYOXALATE; CONTINUOUS ADDITION; HALLUCINOGENS; ALKALOIDS;
D O I
10.1016/0003-2670(95)00257-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The continuous addition of reagent technique was used for the determination of hallucinogenic alkaloids such as harmaline, harmalol, harmine, harmol and harmane by measuring the chemiluminescence (CL) produced in the reaction with the bis(2,4-dinitrophenyl) oxalate/hydrogen peroxide system; this was the first reported use of peroxyoxalate chemiluminescence for these hallucinogens. The ability of this technique to reduce background emission in peroxyoxalate CL determinations was exploited to develop a sensitive method for the determination of the above mentioned hallucinogens. The method features linear responses over 2 orders of magnitude, relative standard deviations of ca. 3% and detection limits in the picomole range, in addition to a high selectivity. Also it compares favourably in terms of sensitivity with that based on another well-known peroxyoxalate reagent, viz. bis(2,4,6-trichlorophenyl) oxalate. It also excels other alternatives based on different techniques in terms of sensitivity. The proposed method was validated for analysis of real samples by applying it to the determination of harmaline in plasma samples.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 28 条
[1]   IDENTIFICATION AND MEASUREMENT OF 6-HYDROXY-1-METHYL-1,2,3,4-TETRAHYDRO-BETA-CARBOLINE BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
BECK, O ;
BOSIN, TR ;
LUNDMAN, A ;
BORG, S .
BIOCHEMICAL PHARMACOLOGY, 1982, 31 (15) :2517-2521
[2]  
Campbell A. K., 1988, CHEMILUMINESCENCE PR
[3]  
CAVIN JC, 1988, J CHROMATOGR, V447, P432, DOI 10.1016/0021-9673(88)90057-X
[4]   POTENTIAL OF THE CONTINUOUS ADDITION OF REAGENT TECHNIQUE FOR CHEMILUMINESCENT REACTION-RATE DETERMINATIONS [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1994, 285 (03) :301-308
[5]   IMPROVED PEROXYOXALATE CHEMILUMINESCENCE-BASED DETERMINATIONS BY USE OF CONTINUOUS REAGENT ADDITION TO REMOVE BACKGROUND EMISSION [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4079-4084
[6]  
HADDAD LM, 1990, CLIN MANAGEMENT POIS, pCH42
[7]   EVALUATION OF ARYL OXALATES FOR CHEMILUMINESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HONDA, K ;
MIYAGUCHI, K ;
IMAI, K .
ANALYTICA CHIMICA ACTA, 1985, 177 :103-110
[8]   ARYL OXALATE CHEMI-LUMINESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
WEINBERGER, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1985, 4 (07) :170-175
[9]  
KRISHNAMURTHY M, 1987, Indian Journal of Pharmaceutical Sciences, V49, P150
[10]   PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY [J].
KWAKMAN, PJM ;
BRINKMAN, UAT .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :175-192