EFFECT OF CONTRAST CONCENTRATION ON ABDOMINAL ENHANCEMENT IN THE RABBIT - SPIRAL COMPUTED-TOMOGRAPHY EVALUATION

被引:9
作者
BLUEMKE, DA [1 ]
FISHMAN, EK [1 ]
ANDERSON, JH [1 ]
机构
[1] JOHNS HOPKINS MED INST,RUSSELL H MORGAN DEPT RADIOL & RADIOL SCI,BALTIMORE,MD 21205
关键词
COMPUTED TOMOGRAPHY (CT); HELICAL (SPIRAL) TECHNOLOGY; CONTRAST MEDIA; LIVER CT;
D O I
10.1016/S1076-6332(05)80170-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We examined the effect of varying the concentration of a nonionic iodinated contrast agent on hepatic and abdominal vascular enhancement using spiral computed tomography (CT) scanning. Methods. Spiral CT scans of 10 New Zealand male rabbits were obtained after intravenous injection of 240 mg I/ml iohexol and 350 mg I/ml iohexol injected at a rate of 2 ml/sec. Each animal was studied at both concentrations using four different contrast volumes: 2.3, 1.7, 1.1, and 0.57 ml/kg. Enhancement values of the aorta, hepatic veins, inferior vena cava, and hepatic parenchyma were measured using a region-of-interest cursor. Results. At all contrast doses, equal volumes of contrast iohexol-350 resulted in statistically higher hepatic (p less than or equal to .003, paired Student's t test) as well as vascular (p < .04) enhancement compared with iohexol-240. The slopes and intercepts of the enhancement curves for iohexol-350 and iohexol-240 were not statistically different (p much greater than .05) when enhancement was plotted as a function of total grams of iodine administered. Conclusion. With spiral CT scanning, appropriate contrast doses and relative costs per dose of iohexol should be considered on the basis of total iodine load administered rather than total volume administered.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 20 条
[1]   CONTRAST MATERIAL FOR COMBINED ABDOMINAL AND PELVIC CT - CAN COST BE REDUCED BY INCREASING THE CONCENTRATION AND DECREASING THE VOLUME [J].
BAKER, ME ;
BEAM, C ;
LEDER, R ;
GULLIVER, D ;
PAINE, SS ;
DUNNICK, NR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :637-641
[2]   COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY [J].
BERLAND, LL ;
LEE, JY .
INVESTIGATIVE RADIOLOGY, 1988, 23 (12) :918-922
[3]   DOSE REQUIREMENTS FOR A NONIONIC CONTRAST AGENT FOR SPIRAL COMPUTED-TOMOGRAPHY OF THE LIVER IN RABBITS [J].
BLUEMKE, DA ;
FISHMAN, EK ;
ANDERSON, JH .
INVESTIGATIVE RADIOLOGY, 1994, 29 (02) :195-200
[4]   CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION [J].
BURGENER, FA ;
HAMLIN, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :351-358
[5]   HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ ;
CONFER, SR .
RADIOLOGY, 1993, 188 (03) :627-631
[6]   BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION [J].
CLAUSSEN, CD ;
BANZER, D ;
PFRETZSCHNER, C ;
KALENDER, WA ;
SCHORNER, W .
RADIOLOGY, 1984, 153 (02) :365-368
[7]   DOES DILUTION OF CONTRAST-MEDIA AFFECT CONTRAST ENHANCEMENT - AN EXPERIMENTAL-STUDY IN RATS [J].
DEAN, PB ;
KIVISAARI, L ;
KORMANO, M .
INVESTIGATIVE RADIOLOGY, 1988, 23 :S118-S121
[8]   CONTRAST ENHANCEMENT PHARMACOKINETICS OF 6 IONIC AND NON-IONIC CONTRAST-MEDIA [J].
DEAN, PB ;
KIVISAARI, L ;
KORMANO, M .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :368-374
[9]   HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION [J].
DEAN, PB ;
VIOLANTE, MR ;
MAHONEY, JA .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :158-161
[10]   INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS [J].
DODD, GD ;
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :643-645