THE RESPONSE BEHAVIOR OF LIF-MG, CU, P THERMOLUMINESCENCE DOSIMETERS TO HIGH-ENERGY ELECTRON-BEAMS USED IN RADIOTHERAPY

被引:15
作者
BARTOLOTTA, A
BRAI, M
CAPUTO, V
DILIBERTO, R
DIMARIANO, D
FERRARA, G
PUCCIO, P
SANTAMARIA, AS
机构
[1] UNIV PALERMO,IST BIOCOMUNICAZ,PALERMO,ITALY
[2] OSPED ONCOL M ASCOLI,SERV FIS SANIT,PALERMO,ITALY
[3] UNIV PALERMO,DIPARTIMENTO INGN NUCL,PALERMO,ITALY
[4] CTR RIFERIMENTO REG CONTROLLO RADIOATTIVITA AMBIE,PALERMO,ITALY
关键词
D O I
10.1088/0031-9155/40/2/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To ensure the effectiveness of radiation-therapy treatments, both in-phantom and in-patient reliable dose measurements are required. Thermoluminescence dosimeters are used commonly for both applications. Among the various available materials, the relatively new LiF: Mg, Cu, P phosphor is a suitable candidate for quality control of in vivo dosimetry in electron-beam therapy. The response behaviour of LiF:Mg, Cu, P chips to 6-21 MeV electron beams used in radiotherapy was studied. Batch homogeneity, dose linearity, sensitivity change after use, dose and dose-rate response, energy dependence and fading characteristics were investigated. The contribution from each factor to the overall uncertainty in dose measurement was evaluated. The results of this work show that the LiF:Mg,Cu,P chips are comparable to the commonly used LiF:Mg, Ti ones, and support their use for in vivo electron-beam dosimetry to an accuracy within +/-10%.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 24 条
[11]   X-RAY SURFACE DOSE MEASUREMENTS USING TLD EXTRAPOLATION [J].
KRON, T ;
ELLIOT, A ;
WONG, T ;
SHOWELL, G ;
CLUBB, B ;
METCALFE, P .
MEDICAL PHYSICS, 1993, 20 (03) :703-711
[12]   QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .1. ENTRANCE DOSE MEASUREMENTS, A RELIABLE PROCEDURE [J].
LEUNENS, G ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1990, 17 (02) :141-151
[13]   QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .2. DETERMINATION OF THE TARGET ABSORBED DOSE [J].
LEUNENS, G ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1990, 19 (01) :73-87
[14]  
ONORI S, 1990, RADIAT PROT DOSIM, V34, P287
[15]   A SYSTEM FOR ELECTRON THERAPY DOSIMETRY SURVEYS WITH THERMO-LUMINESCENCE DOSIMETERS [J].
SOARES, CG ;
EHRLICH, M ;
PADIKAL, TN ;
GROMADZKI, ZC .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1007-&
[16]  
STANTON A, 1987, PRIMER BIOSTATISTICS
[17]  
WANG SS, 1986, RADIAT PROT DOSIM, V14, P223
[18]  
1992, ISO3 INT ORG STAND W
[19]  
1976, ICRU24 REP
[20]  
1984, AAPM13 REP