ULTRATHIN POROUS CARBON-FILMS AS AMPEROMETRIC TRANSDUCERS FOR BIOCATALYTIC SENSORS

被引:44
作者
WANG, J [1 ]
CHEN, Q [1 ]
RENSCHLER, CL [1 ]
WHITE, C [1 ]
机构
[1] SANDIA NATL LABS,DIV 1812,ALBUQUERQUE,NM 87185
关键词
D O I
10.1021/ac00085a011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel ultrathin (0.4 mu m) porous carbon films are employed as transducers for amperometric biosensors. Such foamlike nanoscopic films couple the advantages of high enzyme loadings (within the micropore hosts) and large microscopic area with a small geometric area. Both electropolymerization and metalization are used to entrap the enzyme within the micropores. Scanning electron microscopy sheds useful insights into the unique morphology of the growing enzyme layer. The greatly enhanced sensitivity is coupled with a fast and stable response. Factors influencing the performance of porous-film-based biosensors are examined and discussed. The improved performance is illustrated in connection with glucose and phenol sensors. The latter offers a remarkably low detection limit of 2.5 x 10(-8) M. The new nanoscopic foams should prove useful for many other electroanalytical applications.
引用
收藏
页码:1988 / 1992
页数:5
相关论文
共 11 条
[1]   MIXED IMMOBILIZED ENZYME-POROUS ELECTRODE REACTOR [J].
BLAEDEL, WJ ;
WANG, J .
ANALYTICAL CHEMISTRY, 1980, 52 (09) :1426-1429
[2]   ELECTROCHEMICAL FABRICATION OF AMPEROMETRIC MICROENZYME SENSOR [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
YUKIASHI, T ;
USHIODA, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (03) :702-706
[3]   ENZYME-BASED ELECTROCHEMICAL BIOSENSORS [J].
KOBOS, RK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (01) :6-9
[4]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[5]   VOLTAMMETRIC MEASUREMENTS OF REVERSIBLE AND QUASI-REVERSIBLE REDOX SPECIES USING CARBON-FILM BASED INTERDIGITATED ARRAY MICROELECTRODES [J].
NIWA, O ;
TABEI, H .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :285-289
[6]   CARBON-FILMS FROM POLYACRYLONITRILE [J].
RENSCHLER, CL ;
SYLWESTER, AP ;
SALGADO, LV .
JOURNAL OF MATERIALS RESEARCH, 1989, 4 (02) :452-457
[7]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[8]  
Turner A.P.F., 1987, BIOSENSORS FUNDAMENT
[9]   MINIATURIZED GLUCOSE SENSORS BASED ON ELECTROCHEMICAL CODEPOSITION OF RHODIUM AND GLUCOSE-OXIDASE ONTO CARBON-FIBER ELECTRODES [J].
WANG, J ;
ANGNES, L .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :456-459
[10]   ENZYME NANOBAND ELECTRODES [J].
WANG, J ;
NASER, N ;
RENSCHLER, CL .
ANALYTICAL LETTERS, 1993, 26 (07) :1333-1346