Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines

被引:11
作者
Ling, Yu [1 ,2 ]
Dou, Zhenlan [1 ]
Gao, Qiang [1 ]
Cai, Xu [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, WPRC, Shanghai 200240, Peoples R China
[2] Shanxi Datong Univ, Dept Elect Engn, Datong 037003, Shanxi, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, SKLOE, Shanghai 200240, Peoples R China
关键词
Doubly fed induction generator (DFIG); low-voltage ride-through (LRVT); protection; pitch control;
D O I
10.1260/0309-524X.36.5.535
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
So far, active crowbars are a preferred technique for doubly fed induction generator (DFIG) wind turbines, which is used to protect the power converter against over-current and undesirably high dc link voltage during voltage dip. However, its main drawbacks are that (1) the DFIG absorbs reactive power from the grid during grid voltage dips, (2) the crowbar activation increases the acceleration of the rotor and so, deteriorates the dynamic stability of DFIG, and (3) the control is not flexible for long-time voltage sags. In the paper, three different initiating logic control methods of crowbar protection are compared, and how lowvoltage ride-through (LVRT) characteristics of DFIG wind turbines with active crowbar are affected by different switching logic control modes of the crowbar are investigated. According to the comparison results, an improved crowbar switching control strategy is proposed to reduce its operation time and improve the LVRT capability of DFIG wind turbines. In addition, an emergency pitch blade angle control scheme to reduce the acceleration of the rotor and prevent the over-speeding of rotor is presented in detail, and as a result, the LVRT capability of DFIG wind turbines is enhanced even during long-time voltage sags. Finally, the presented control strategies are validated in simulation tool Matalab/ Simulink for a 1.5MW generator.
引用
收藏
页码:535 / 551
页数:17
相关论文
共 26 条
[21]  
Rodruiguez M., 2005, 2005 EUR C POW EL AP, V2005, P1
[22]   Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault [J].
Sun, T ;
Chen, Z ;
Blaabjerg, F .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :1991-1997
[23]  
Zhan C., 2006, The 8th IEE International Conference on AC and DC Power Transmission (ACDC 2006), P79, DOI 10.1049/cp:20060017
[24]   Direct power control of DFIG with, constant switching frequency and improved transient performance [J].
Zhi, Dawei ;
Xu, Lie .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :110-118
[25]  
Zhou Peng, 2007, International Conference on Electrical Machines and Systems 2007, P259
[26]   Improved Direct Power Control of a DFIG-Based Wind Turbine During Network Unbalance [J].
Zhou, Peng ;
He, Yikang ;
Sun, Dan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (11) :2465-2474