双源CT前瞻性心电门控大螺距螺旋扫描冠状动脉成像研究进展

被引:12
作者
赵磊
刘挨师
机构
[1] 内蒙古医学院附属医院CT室
关键词
D O I
10.13437/j.cnki.jcr.2011.10.017
中图分类号
R816.2 [心脏血管系];
学科分类号
100106 [放射医学];
摘要
<正>近十年来,由于16~64层CT的研发与应用使得CT冠状动脉成像(CTCA)由单纯科学研究转变到了临床应用。目前CTCA已广泛应用于冠状动脉粥样硬化性心脏病的诊断与随访、冠状动脉旁路移植术后及支架置入术后(直径3 mm以上的近端支架)的评估与随访。新近的Meta分析及多中心临床研究均认为CTCA具有较高阳性预测值及极高阴性预测值,更适用于可疑冠状动脉疾病(CAD)的排查。成本效益分析也显示建立在严格规范适应证与禁忌证的基础上使用CTCA可以大幅降低医疗成本。
引用
收藏
页码:1557 / 1559
页数:3
相关论文
共 12 条
[1]
High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates [J].
Goetti, Robert ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Fischer, Michael Alexander ;
Karlo, Christoph ;
Baumueller, Stephan ;
Scheffel, Hans ;
Alkadhi, Hatem ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2010, 20 (11) :2565-2571
[2]
Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode [J].
Wolf, Florian ;
Leschka, Sebastian ;
Loewe, Christian ;
Homolka, Peter ;
Plank, Christina ;
Schernthaner, Ruediger ;
Bercaczy, Dominik ;
Goetti, Robert ;
Lammer, Johannes ;
Friedrich, Guy ;
Marincek, Borut ;
Alkadhi, Hatem ;
Feuchtner, Gudrun .
EUROPEAN RADIOLOGY, 2010, 20 (09) :2084-2091
[3]
Prospective helical acquisition for coronary CT angiography [J].
Dewey, Marc .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01) :109-110
[4]
Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality [J].
DeFrance, Tony ;
Dubois, Eric ;
Gebow, Dan ;
Ramirez, Alex ;
Wolf, Florian ;
Feuchtner, Gudrun M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01) :99-107
[5]
Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients [J].
Adler, Ghazal ;
Meille, Laurent ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Capderou, Andre ;
Paul, Jean-Francois .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1118-1123
[6]
Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience [J].
Leschka, Sebastian ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Goetti, Robert ;
Schertler, Thomas ;
Scheffel, Hans ;
Plass, Andre ;
Falk, Volkmar ;
Feuchtner, Gudrun ;
Marincek, Borut ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2009, 19 (12) :2896-2903
[7]
Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience [J].
Lell, Michael ;
Marwan, Mohamed ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Flohr, Thomas ;
Allmendinger, Thomas ;
Kalender, Willi ;
Ertel, Dirk ;
Thierfelder, Carsten ;
Kuettner, Axel ;
Ropers, Dieter ;
Daniel, Werner G. ;
Achenbach, Stephan .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2576-2583
[8]
Diagnostic Accuracy of Coronary Computed Tomography Angiography.[J].Gianluca Pontone;Daniele Andreini;Antonio L. Bartorelli;Sarah Cortinovis;Saima Mushtaq;Erika Bertella;Andrea Annoni;Alberto Formenti;Enrica Nobili;Daniela Trabattoni;Piero Montorsi;Giovanni Ballerini;Piergiuseppe Agostoni;Mauro Pepi.Journal of the American College of Cardiology.2009, 4
[9]
Cardiac spiral dual-source CT with high pitch: a feasibility study [J].
Ertel, Dirk ;
Lell, Michael M. ;
Harig, Frank ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2009, 19 (10) :2357-2362
[10]
Prospectively gated low-dose CCTA: 24 months experience in more than 2;000 clinical cases.[J].James P. Earls;Elizabeth C. Schrack.The International Journal of Cardiovascular Imaging.2009, 2