High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

被引:94
作者
Goetti, Robert [2 ]
Feuchtner, Gudrun [2 ]
Stolzmann, Paul [2 ,3 ]
Desbiolles, Lotus [2 ]
Fischer, Michael Alexander [2 ]
Karlo, Christoph [2 ]
Baumueller, Stephan [2 ]
Scheffel, Hans [2 ,3 ]
Alkadhi, Hatem [2 ,3 ]
Leschka, Sebastian [1 ,2 ]
机构
[1] Kantonsspital, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
High-pitch; Computed tomography; Systolic reconstruction; Coronary arteries; Heart rate; Radiation dose; SOURCE COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMAGE QUALITY; ROW CT; WINDOWS; AORTA;
D O I
10.1007/s00330-010-1838-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs). Eighty consecutive patients (15 women, age 67 +/- 14 years) with HR a parts per thousand yen70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated. Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (kappa = 0.62). HRs were similar in groups A and B (85 +/- 13 bpm vs 85 +/- 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 +/- 0.3 mSv for chest CTA. A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (a parts per thousand yen70 bpm) significantly improves coronary artery image quality at a low radiation dose.
引用
收藏
页码:2565 / 2571
页数:7
相关论文
共 30 条
[1]
In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[3]
Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients [J].
Adler, Ghazal ;
Meille, Laurent ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Capderou, Andre ;
Paul, Jean-Francois .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1118-1123
[4]
Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography [J].
Araoz, Philip A. ;
Kirsch, Jacobo ;
Primak, Andrew N. ;
Braun, Natalie N. ;
Saba, Osama ;
Williamson, Eric E. ;
Harmsen, W. Scott ;
Mandrekar, Jayawant N. ;
McCollough, Cynthia H. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) :837-845
[5]
Austen W G, 1975, Circulation, V51, P5
[6]
Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population [J].
Bamberg, Fabian ;
Sommer, Wieland H. ;
Schenzle, Jan C. ;
Becker, Christoph R. ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2010, 20 (06) :1331-1336
[7]
Duration of diastole and its phases as a function of heart rate during supine bicycle exercise [J].
Chung, CS ;
Karamanoglu, M ;
Kovács, SJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (05) :H2003-H2008
[8]
Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography [J].
Gerber, TC ;
Kuzo, RS ;
Morin, RL .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) :165-176
[9]
High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible? [J].
Goetti, Robert ;
Baumueller, Stephan ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Karlo, Christoph ;
Alkadhi, Hatem ;
Leschka, Sebastian .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :938-944
[10]
Halliburton Sandra S, 2008, J Cardiovasc Comput Tomogr, V2, P392, DOI 10.1016/j.jcct.2008.09.003